204_58300000120957_ARA_EN_E.doc – 29.08.a
Seite 36 von 37
7.13.2 Cause of the problem
There are defects in the mould manufacturing
7.13.3 Solution
Change the regulator.
From FD 8904, the mould of the regulator steam was improved.
7.14 Steam station stop working
7.14.1 Problem
description
In devices whit FD<9209 the steam station stop working
7.14.2 Cause of the problem
Relay from the PCB failure
7.14.3 Solution
Change the PCB
From FD9209 the supplier of the wrong relay was changed.