background image

Installation Instructions

for the DS970 Series

TriTech

®

 Microwave/PIR Intrusion Detectors

1.0

Specifications

Dimensions (HxWxD):

5 in. x 2.8 in. x 2.2 in.
(12.7 cm x 7.1 cm x 5.6 cm)

Input Power:

9 to 15 VDC, 22 mA DC nominal (up to
52 mA DC during walk testing, stored
alarms, or trouble conditions). Use only
an Approved Limited Power Source.

Standby Power:

No internal standby battery. Standby
power 

must

 be provided by  an Approved

Limited Power Source. Twenty-two
mAh required for each hour of standby
time needed. 

Four hours (88 mAh)

minimum are required for UL Listed
Requirements.

Alarm Relay:

Silent operating Normally Closed reed
relay. Contacts rated 3 watts, 125 mA,
28 VDC maximum for DC resistive
loads; and protected by a 4.7 ohm, 0.5
watt resistor in the common "C" leg of
the relay. To be connected to a SELV
(Safety Extra-Low Voltage) circuit only.
Do 

not 

use with capacitive or inductive

loads.

Tamper:

Normally Closed (with cover on).
Contacts rated at 28 VDC, 125 mA max.
To be connected to a SELV (Safety Extra-
Low Voltage) circuit only.  Connect
tamper circuit to 24-hour protection
circuit.

Trouble

:

Solid State output shorts to ground (-)
when the detector is in a supervision
trouble condition. Maximum load is 25
mA, Vsat @ 10 mA  =  0.5 VDC.

Temperature Range:

-40°F to +120°F (-40°C to +49°C).
For UL Listed requirements, the
temperature range is +32°F to +120°F
(0°C to +49°C), indoor use.

Microwave Frequency:

DS970:

10.525 GHz (UL Listed)

DS970A:

10.687 GHz (Export only, 

not

 UL  Listed)

DS970B:

9.9 GHz (Export only, 

not

 UL Listed))

Coverage:
Broad (standard):

70 ft. by 70 ft. (21 m by 21 m)

Long Range (optional):

100 ft. by 10 ft. (30 m by 3 m)

Internal Pointability:

+2° to –10° Vertical, ±10° Horizontal.

Options:

B328 Gimbal Mount Bracket, B335
Low Profile Swivel Mount Bracket,
B338 Ceiling Mount Bracket, OLR92
Long Range Barrier Lens, TC6000
Test Cord

NOTE:

Use of a bracket may reduce range and increase dead zone
areas.

•  

Reading Bosch Security Systems, Inc. Product Date Codes

For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at: 

http://www.boschsecurity.com/

datecodes/

Compliance:

 This device complies with Part 15 of the FCC Rules

and with RSS-210 of Industry and Science Canada. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including

interference that may cause undesirable operation.

Changes or modifications not expressly approved by Bosch
Security Systems can void the user’s authority to operate the
equipment.

2.0

Installation Considerations

NOTE:

The DS970 is 

not 

recommended for installations containing

pets or small animals.  Use the DS820 or DS835 for such
installations.

Never

 install the detector in an environment that causes an alarm

condition in one technology. Good installations start with the LED

OFF

 when there is no target motion. It should never be left to

operate with the tri-color LED in a constant or intermittent green,
yellow, or red condition.

Point the unit away from outside traffic (roads/alleys).

NOTE:

Microwave energy will pass through glass and most
common non-metallic construction walls.

Avoid installations where rotating machines (e.g. ceiling fans)
are normally in operation within the coverage pattern. Point the
unit away from glass exposed to the outdoors and objects that
may change temperature rapidly.

NOTE:

The PIR detector will react to objects rapidly changing
temperature within its field-of-view.

Eliminate interference from nearby outside sources.

3.0

Mounting

Select a location likely to intercept an intruder moving 

across

 the

coverage pattern. The surface should be solid and vibration-
free. Mounting height range is 6 to 8 ft. (1.8 to 2.4 m).
Recommended mounting height is 7.5 ft. (2.3 m).

Remove the cover. Insert a flathead screwdriver into the locking
tab hole at the bottom front of the detector. Pull the cover up and
forward.

Tri-color

LED

Vertical

Adjust

Screw

Terminal

Strip

MW

- 4°
- 8°

Vertical Adjust

Scale

LED

On/Off

Pins

On

Off

Memory

Jumper

Microwave

Range Adjust

_ +

NO C NC T

T M TR

Motion Monitor

and

Anti-Mask

Selection Pins

PIR

Sensitivity

Selection Pins

Trouble

Memory

Microwave Noise Voltage Pins

30

1

INT

STD

Off

*

* = Only cut if using Memory Feature.

Walk test before cutting.

PIR  Noise

Voltage Pins

Look Down

Mask

Corner Mount

Knockout (4)

Surface Mount

Knockout (2)

Wire
Entrances

Bracket Mount

Knockout

Vertical Adjust
Screw Mount

Cover Tab and

Locking Screw Hole

Wire
Entrances

Summary of Contents for TriTech DS970 Series

Page 1: ...with RSS 210 of Industry and Science Canada Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesirable operation Changes or modifications not expressly approved by Bosch Security Systems can void the user s authority to operate the equipment 2 0 Insta...

Page 2: ... cycle NOTE During walk testing the LED will light for the first technology microwave or PIR and then light red to indicate a detector alarm The LED will not indicate activation of the second technology by lighting its color 6 0 Feature Selection 6 1 LED On Off Pins The ON position allows operation of the tri color LED If LED indication is not desired after setup and walk tests are completed place...

Page 3: ...rom the unit Repeat from above for the upper boundary The center of the pattern should not be tilted upward NOTE If desired coverage cannot be achieved try angling the coverage pattern up or down to assure the pattern is not aimed too high or low The angle of the PIR pattern may be vertically positioned between 10 and 2 by loosening the Vertical Adjust screw and sliding the circuit board up or dow...

Page 4: ...uld occur reset the detector by removing and then re applying its power The trouble condition will also be reset by the next detector alarm after a 10 second period of no alarms from either technology Motion Monitor Supervision This feature verifies that each technology has a clear view of the detection area When selected a supervision timer is activated which gives the detector the ability to ind...

Reviews: