20
en | Installation
AEGIS UFLED
F.01U.123.987 | 1.0 | 2010.04
Installation Manual
Bosch Security Systems
Note:
Potentiometer Factory set at mid-point 500 Lux ON and 850 Lux
OFF (approximately).
Check the photocell functions by covering with black tape and
having the telemetry link closed. The photocell operation has an
in-built delay of up to 5 seconds.
3.2.4
Power adjustment
To adjust power, first unscrew the sealing cap; the
potentiometer is set at the maximum calibration point (fully
clockwise). To decrease the power, turn the potentiometer
counter clockwise.
3.3
Remote Switching
Various switching configurations can be made using an
interface cable. Commonly used switching configurations are
explained below.
3.3.1
Camera (or other switching device) Leading
The illuminator may be activated remotely by a volt-free contact
latched across the TELEMETRY input. Use interface cable
UFLED-CI-5M.
NOTICE!
Replace the sealing cap after adjustment to ensure water
ingress protection.
1
UFLED Illuminator
2
Camera
3
UFLED-CI-5M
Summary of Contents for UFLED
Page 1: ...AEGIS UFLED UFLED en Installation Manual ...
Page 2: ......
Page 25: ......
Page 26: ...Bosch Security Systems Inc www boschsecurity com Bosch Security Systems Inc 2010 ...