4
en | Installing the UMS Series
UMS Series Public View System
F01U029703 | 1.0 | 2006.07
Installation Manual
Bosch Security Systems, Inc.
To mount the UMS Series you must use the following hardware:
The UMS Series is available in a variety of mount configurations. For specific directions on
mounting the unit, see the manual that came with your mount. Once the UMS is mounted,
remove the clear protective plastic covers and
continue the installation procedure.
3.3
Power Connection
Attach the two (2) 24 VAC power leads to your transformer/power supply. It is recommended
to use the UMP-24V4P0-60 power supply, otherwise see Section 3.1,
Power
, on page 3 for the
acceptable voltage range. Once power is supplied, the unit automatically turns on.
3.4
Video Connections
Each UMS Series model offers either a Video In or a Video Out connector.
3.4.1
Video In (UMS-20xxxA models only)
If you have an external video source you would like to use as the auxiliary source, connect the
cable to the
Video In
connector.
3.4.2
Video Out (both models)
To connect the camera to a monitoring station, attach a coax cable to the
Video Out
connec-
tor on the unit to the input connector of the external monitor/recorder.
Ref. # Description
1
2.95-in. (75-mm) mounting hole pattern
2
3.94-in. (100-mm) mounting hole pattern
3
Thumbscrews
4
Sign mounting hole pattern
(To mount a sign, use #8-32 screws with a maximum length of 5/16 in.)
Quantity
Description
4
#10-24 3/8 BHC stainless steel patch lock screws
*
4
#10 plain type stainless steel flat washers
*
* The screws and washers are not provided with the UMS Series.
i
NOTICE!
UMS models that feature an internal card reader do not include a
Video In
connector.