English |
21
Digital detector
UniversalDetect
Max. detection depth
A)
– Metals
100 mm
– Single-phase live cables (110−240 V, 50−60 Hz,
with voltage applied)
B)
50 mm
– Wooden substructures in dry walls
25 mm
C)
Operating temperature
–5 °C to +40 °C
Storage temperature
–20 °C to +70 °C
Operating frequency range
48−52 kHz
Max. magnetic field strength
16 dBµA/m
Max. altitude
2000 m
Relative air humidity
–
<Metal>
and
<Wood>
operating mode
30−80 %
–
<Current>
operating mode
< 50 %
Pollution degree according to IEC 61010-1
2
D)
Batteries
4 × 1.5 V LR3 (AAA)
Approx. operating time
4 h
Weight according to EPTA-Procedure 01:2014
0.34 kg
A) Depends on operating mode, material and size of the objects, as well as material and condition
of the base material
B) Lower detection depth with non-live wires
C) equal to two plasterboard panels
D) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.
The serial number
(7)
on the type plate is used to clearly identify your measuring tool.
u
The accuracy and detection depth of the measuring result may be negatively af-
fected if the condition of the substrate is unfavorable.
Assembly
Inserting/changing the Batteries
It is recommended that you use alkaline manganese batteries to operate the measuring
tool.
Bosch Power Tools
1 609 92A 6H8 | (02.07.2021)
Summary of Contents for UniversalDetect
Page 3: ... 3 1 2 3 4 5 6 8 7 a b c d e f 9 Bosch Power Tools 1 609 92A 6H8 02 07 2021 ...
Page 4: ...4 A B 6 x x z 9 8 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...
Page 5: ... 5 C D Bosch Power Tools 1 609 92A 6H8 02 07 2021 ...
Page 204: ...204 فارسی 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...
Page 208: ...IV 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...