22
| English
Do not use disposable batteries that have a rated voltage of greater than 1.5 V.
To open the battery compartment cover
(1)
, push it away from the battery compartment
in the direction of the arrow. Insert the batteries.
When inserting the batteries, ensure that the polarity is correct according to the illustra-
tion on the inside of the battery compartment.
The battery symbol
(f)
in the display status bar shows the current state of charge of the
batteries.
If the symbol opposite appears in the display status bar, the measuring tool
can continue to be used for up to another 15 minutes. Change the batteries.
Always replace all the batteries at the same time. Only use batteries from the same man-
ufacturer and which have the same capacity.
u
Take the batteries out of the measuring tool when you are not using it for a pro-
longed period of time.
The batteries can corrode and self-discharge during pro-
longed storage in the measuring tool.
Operation
u
Protect the measuring tool from moisture and direct sunlight.
u
Do not expose the measuring tool to any extreme temperatures or variations in
temperature. In case of large variations in temperature, leave the measuring tool
to adjust to the ambient temperature before switching it on.
The accuracy of the
measuring tool and the functionality of the display may be compromised if exposed to
extreme temperatures or variations in temperature.
u
Avoid hard knocks to the measuring tool or dropping it.
After severe external influ-
ences and in the event of abnormalities in the functionality, you should have the
measuring tool checked by an authorised
Bosch
after-sales service agent.
u
Certain ambient conditions fundamentally impair the measuring results. These
include, e.g. the proximity of devices that generate strong electric, magnetic or
electromagnetic fields, moisture, metal building materials, foil-laminated insula-
tion materials or conductive wallpaper or tiles.
Therefore, also refer to other in-
formation sources (e.g. construction plans) before drilling, sawing or routing into
walls, ceilings or floors.
u
Hold the measuring tool by the intended gripping surface (9) only, so as not to
influence the measurement.
u
Do not attach any stickers or labels to the sensor area
(6) on the rear of the
measuring tool.
Metal labels in particular will affect measuring results.
1 609 92A 6H8 | (02.07.2021)
Bosch Power Tools
Summary of Contents for UniversalDetect
Page 3: ... 3 1 2 3 4 5 6 8 7 a b c d e f 9 Bosch Power Tools 1 609 92A 6H8 02 07 2021 ...
Page 4: ...4 A B 6 x x z 9 8 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...
Page 5: ... 5 C D Bosch Power Tools 1 609 92A 6H8 02 07 2021 ...
Page 204: ...204 فارسی 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...
Page 208: ...IV 1 609 92A 6H8 02 07 2021 Bosch Power Tools ...