Feature
Description
Default Options
ENABLE PAN LIM.
Enables limits and values in degrees
taken by the device in pan.
Enables or disables complete rotation
for scan/patrol/autopan movements
(this function is useful when using
accessories with external cables, such
as infrared spotlights, where
continuous rotation of the UPH could
break the accessories themselves).
NO
YES, NO
START PAN
Enables the location that the UPH
begins to pan.
+0.00
-180.00° to
+180.00°
END PAN
Enables the location that the UPH stops
panning.
+0.00
-180.00° to
+180.00°
ENABLE TILT LIM.
Enables limits and values in degrees
taken by the device in tilt.
NO
YES, NO
START TILT
Enables the location that the UPH
begins to tilt.
+0.00
-40.00° to +90.00°
END TILT
Enables the location that the UPH stops
tilting.
+0.00
-40.00° to +90.00°
RAMP TYPE
Changes start and stop times for the
UPH. The higher the number, the
greater the acceleration/deceleration
during starting/stopping.
012
000 to 012
Preset/Patrol/Autopan
The Preset/Patrol/Autopan menu sets the movement limits related to the UPH.
MOTION PARAMETERS
MENU
> 1 - PRESET
>
2 - SPECIAL PRESET PARAM. >
3 - HOME POSITION
>
4 - PATROL
>
5 - AUTOPAN
>
8 - MOTIONS RECALL
>
12.3.3