19
6 720 807 794 (2013/04)
UNIMAT
• For information and instructions regarding the
requirements for the boiler installation room, see
chapter 10.2, page 67.
• These dimensions are designed for 100-mm thick
insulation.
• Connections W32.509 and W32.510 can be made on
the right hand or left hand side.
• Dimensions given with ± 1 % tolerance; weights given
with ± 3 % tolerance.
• Pipe thread to DIN 2999.
1000 / 672
1520
1840
760
780
1419
795
750
0
1086
1417
886
1217
547
1110 / 752
1520
1885
760
750
1529
850
900
0
1166
1472
966
1272
584
1300 / 885
1520
2025
760
765
1719
945
1100
0
1299
1607
1099
1407
647
1350 / 965
1520
2215
760
855
1769
970
1100
0
1379
1767
1179
1567
697
1550 / 1045
1520
2260
760
825
1969
1070
1350
0
1459
1832
1259
1632
734
1600 / 1072
1520
2230
760
900
2019
1095
1350
250
1486
1897
1286
1697
747
1750 / 1178
1920
2330
960
930
2169
1170
1550
250
1592
2017
1392
1817
797
1900 / 1258
1920
2270
960
930
2319
1245
1700
250
1672
2117
1472
1917
847
2050 / 1365
1920
2390
960
975
2469
1320
1700
250
1779
2247
1579
2047
897
2200 / 1472
1920
2470
960
1005
2619
1395
2000
250
1886
2367
1686
2167
947
Heat
exchanger
Measurements
Port
Shipping weight
Water capacity
per bundle
L 3
L4
additional
weight with
bypass
W32.506
1 bundle
2 bundle
ECO 7
[mm]
[mm]
[mm]
[DN]
[~kg]
[~kg]
[~kg]
[l]
390 / 245
353
380
353
285
1"
100
150
20
10
510 / 325
353
380
353
360
1"
130
200
40
15
600 / 378
353
380
353
410
1"
160
240
60
20
690 / 432
353
380
353
485
1"
190
290
80
26
750 / 485
353
380
353
510
1"
220
340
100
29
890 / 592
353
418
353
635
1"
270
410
150
37
930 / 618
353
418
353
660
1"
300
450
160
42
1000 / 672
553
560
553
710
1"
360
530
170
46
1110 / 752
553
530
553
785
1"
400
580
210
52
1300 / 885
553
545
553
910
1"
480
680
290
64
1350 / 965
553
635
553
1010
1"
550
800
380
85
1550 / 1045
553
605
553
1085
1"
650
940
440
98
1600 / 1072
553
680
553
660
1"
710
1050
420
119
1750 / 1178
753
710
753
690
1''
850
1230
810
125
1900 / 1258
753
710
753
690
1"
940
1340
860
148
2050 / 1365
753
755
753
735
1"
1070
1550
960
173
2200 / 1472
753
785
753
753
1"
1200
1740
1090
200
Table 12 Main dimensions
Heat
exchanger
Measurements
L 1
1)
L 2
1)
B 1
2)
B 2
B 3
B 4
H 1
H 2
H 3
without
bypass
with
bypass
without
bypass
with
bypass
without
bypass
with
bypass
without
bypass
with
bypass
ECO 7
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
Table 11 Main dimensions
For the allocation of the ECO 7 stand-alone
heat exchanger to the boiler size, see
chapter 3.3.2, Tab. 7, page 15.