Technical description
|
29
6 720 807 794 (2013/04)
UNIMAT
Standby loss
The
standby loss
is part of the rated heat input that is
required to achieve the specified boiler water
temperature. The cause of this loss is the cooling down
of the boiler through radiation and convection during the
standby time (burner idle time).
Boiler
type
Boiler size
Max.
rated
output
Boiler
efficiency
Standard
seasonal
efficiency
[to DIN]
[kw]
η
K
1)2)
1) Relative to a system temperature of 80/60 °C. At other system
temperatures, the boiler efficiency changes.
2) Relative to the maximum rated output; for reduced rated
output levels, the boiler efficiency rises accordingly.
η
N
1) 2)
UNIMAT
boiler
UT-L
UT-L 1
650
92.2
94.9
UT-L 2
750
92.4
95.2
UT-L 4
1000
91.8
94.9
UT-L 6
1000
93.3
95.7
UT-L 8
1250
92.4
95.3
UT-L 10
1350
92.9
95.6
UT-L 12
1500
92.6
95.5
UT-L 14
1900
91.4
94.8
UT-L 16
2000
92.3
95.3
UT-L 18
2500
91.7
95.0
UT-L 20
2500
93.1
95.8
UT-L 22
3000
92.7
95.6
UT-L 24
3050
91.3
94.8
UT-L 26
3500
92.7
95.6
UT-L 28
3700
92.3
95.4
UT-L 30
4200
92.0
95.2
UT-L 32
4250
92.0
95.2
UT-L 34
5200
91.9
95.2
UT-L 36
5250
92.6
95.6
UT-L 38
6000
93.0
95.8
UT-L 40
6500
91.3
94.9
UT-L 42
7700
92.0
95.2
UT-L 44
8000
92.8
95.6
UT-L 46
9300
92.2
95.4
UT-L 48
10000
93.1
95.8
UT-L 50
11200
92.2
95.4
UT-L 52
12000
92.6
95.6
UT-L 54
12600
92.7
95.6
UT-L 56
14000
93.5
96.0
UT-L 58
14700
92.2
95.4
UT-L 60
16400
93.4
96.0
UT-L 62
17500
92.9
95.7
UT-L 64
19200
92.8
95.7
Table 17 Boiler efficiency and standard seasonal
efficiency [to DIN] for UNIMAT boilers UT-L
Boiler type Boiler size
Max.
rated
output
Standby loss
q
B
1)
1) Relative to a system temperature of 80/60 °C
[kw]
[kW]
%
2)
2) Relative to the maximum rated output
UNIMAT
UT-L boiler
UT-L 1
650
2.16
0.333
UT-L 2
750
2.36
0.314
UT-L 4
1000
2.80
0.28
UT-L 6
1000
2.80
0.28
UT-L 8
1250
3.20
0.256
UT-L 10
1350
3.35
0.248
UT-L 12
1500
3.57
0.238
UT-L 14
1900
4.12
0.217
UT-L 16
2000
4.24
0.212
UT-L 18
2500
4.85
0.194
UT-L 20
2500
4.85
0.194
UT-L 22
3000
5.41
0.18
UT-L 24
3050
5.47
0.179
UT-L 26
3500
5.94
0.17
UT-L 28
3700
6.14
0.166
UT-L 30
4200
6.62
0.158
UT-L 32
4250
6.67
0.157
UT-L 34
5200
7.53
0.145
UT-L 36
5250
7.57
0.144
UT-L 38
6000
8.20
0.137
UT-L 40
6500
8.61
0.132
UT-L 42
7700
9.53
0.124
UT-L 44
8000
9.75
0.122
UT-L 46
9300
10.67
0.115
UT-L 48
10000
11.15
0.111
UT-L 50
11200
11.93
0.107
UT-L 52
12000
12.44
0.104
UT-L 54
12600
12.81
0.102
UT-L 56
14000
13.64
0.097
UT-L 58
14700
14.05
0.096
UT-L 60
16400
15.00
0.091
UT-L 62
17500
15.59
0.089
UT-L 64
19200
16.49
0.086
Table 18 Standby loss for UNIMAT UT-L boilers