AutoDome Easy IP
Connections | en
21
Bosch Security Systems, Inc.
Installation Manual
F01U079609 | 1.0 | 2008.08
5.3
Connecting the Alarm Input
The AutoDome Easy IP provides one (1) alarm input. This alarm
input can be activated by dry contact devices, which can be set
to: alert the operator via on-screen test or through the web
browser; trigger the dome to move to a pre-position, if
configured properly; automatically establish a connection with
a receiving device; and send an alarm e-mail. The default alarm
state is normally open but may be programmed to be normally
closed. To connect the alarm input, do the following:
1.
Locate the cable assembly with a two (2) pin blue mating
connector on one end and the blue and violet flying leads
on the other end.
2.
Connect the ground of the alarm source dry contact to the
blue wire (alarm common).
3.
Connect the alarm out of the alarm source dry contact to
the violet wire (alarm input).
Figure 5.1
N.O. - Normally Open Alarm Connections
Reference Description
1
Dry Contact
2
Alarm Common (blue wire)
3
Alarm Input (violet wire)
Summary of Contents for VEZ IP Series
Page 1: ...AutoDome Easy IP VEZ IP Series en Installation Manual ...
Page 2: ......