30
en | Cable and Wire Standards
AutoDome Power Supply Boxes
F.01U.250.895 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
In a daisy chain configuration, where multiple domes are
connected in series, the 100 Ω resistor must be removed from
all but the last dome. You can daisy chain a maximum of four (4)
AutoDomes.
Figure 3.3
Connections for a Daisy Chain Configuration
3.4.2
Controlling the AutoDome via the RS232 Protocol
(3-wire, full-duplex, single-ended, 50 ft. cable limit)
RS232 is a common, single-ended communication protocol
used for control. Data transmission via 3-wires (TDX, RXD,
common) is from one transmitter to one receiver at relatively
slow baud rates (up to 57.6 Kbaud) and short distances up to
50 ft.
1
C- (Biphase)
9
Dome 3
2
C+ (Biphase)
10
Dome 2
3
Earth Ground
11
Dome 1
4
RxD
12
Head End Biphase
5
TxD
13
C- (Biphase)
6
Signal Ground
14
C + (Biphase)
7
Last Dome Data In/Out
15
Shield
8
P105/P106 Connector in Power
Supply Box
100
Ω
NOTICE!
After making the wire connections for RS232 operation,
reposition the slide switch located on the CPU Module to the
camera head inward and away from the LEDs.