Menu
Description
Sub-menu / Description
BIST
Enters the Perform Built-in Self Tests menu. If
confirmed, the BIST tests start and the results
are displayed.
YES to start test. NO to exit the
menu.
Typical results displayed as follows:
BIST
Exit...
Data Flash: PASS
Bilinx: PASS
FPGA: PASS
Digital I/O 1: PASS
Digital I/O2: PASS
VCA: PASS
Homing: PASS
Internal Temp.
Displays the current dome temperature.
High Temp Events
Displays the number of times the high
temperature threshold is exceeded.
Highest Temp
Displays the highest temperature reached.
Low Temp Events
Displays the number of times the low
temperature threshold is exceeded.
Lowest Temp
Displays the lowest temperature reached.
Security Access
Displays the number of times the locked-
command menu is unlocked.
CTFID Access
Displays the number of times the Configuration
Tool is accessed.
Homing Events
Displays the number of times the AutoDome
was rebooted.
Homing Failed
Displays the number of times the AutoDome
failed to home properly.
Loss Home Events:
Displays the number of times the AutoDome lost
the home position.
Home Position Good
Displays if the current AutoDome home position
is good. Displays YES if good.
Restart Events
Displays the number of restart events.
Low Volt Events
Displays the number of times the AutoDome
dropped below the acceptable voltage limit.
Power Up Events
Displays the number of power up events.
Video Loss Events
Displays the number of time that video was lost.
Alarm Status Submenu
This menu displays the status of the alarm inputs and alarm outputs.
2.11.1
26
en | On-Screen Display Menu Navigation
AutoDome 600 Series Analog PTZ
Camera
2014.11 | 2.1 | F.01U.270.005
User Manual
Bosch Security Systems, Inc.
Summary of Contents for VG5 600 Series
Page 1: ...AutoDome 600 Series Analog PTZ Camera VG5 600 Series en User Manual ...
Page 2: ......
Page 67: ......