Configure VIDEOJET connect 7000 to Operate with a
MIC7000 Camera
To configure alarm inputs and outputs, audio, and video playback for a MIC7000 camera, that
camera must be “bound” to channel 1 (connected to the port labeled PoE on the PCBA) on
VIDEOJET connect 7000.
Configure Alarm Inputs and Outputs
To configure a camera “bound” to channel 1 for alarm inputs and outputs, follow these steps:
4
On the camera “bound” to VIDEOJET connect 7000, verify that the value in the field
Application variant is set to “[camera name] – VJC-7000.” (Access the field from Camera
> Installer Menu in the web browser of the camera.) This variant will align the
appropriate parameters of the camera with the parameters of VIDEOJET connect 7000.
4
In the device VIDEOJET connect 7000, verify that the parameters “Show alarm inputs”
and “Show alarm outputs” are selected in the menu Web Interface > LIVE Functions.
Note: The Interfaces menu, which displays alarm inputs and outputs (alarm I/O), appears only
in the configuration menu of the camera “bound” to VIDEOJET connect 7000 (the camera for
which the value in the field Application variant is set to “[camera name] – VJC-7000”).
Configure Audio
To configure a camera “bound” to channel 1 for audio, follow these steps:
4
On the camera “bound” to VIDEOJET connect 7000, verify that the value in the field
Application variant is set to “[camera name] – VJC-7000.” (Access the field from Camera
> Installer Menu in the web browser of the camera.) This variant will align the
appropriate parameters of the camera with the parameters of VIDEOJET connect 7000.
4
In the device VIDEOJET connect 7000, select the Transmit audio check box in the menu
Web Interface > LIVE Functions.
4
In the device VIDEOJET connect 7000, set the Input volume in the menu Transcoder >
Audio.
Note: The page Camera > Audio (in the configuration menu between Miscellaneous and Pixel
Counter) appears only in the configuration menu of the camera “bound” to VIDEOJET connect
7000.
Configure Video Playback
To configure video playback with VIDEOJET connect 7000, first you must map the device to
record. See Recording, page 38 for details.
15
15.1
15.2
15.3
54
en | Configure VIDEOJET connect 7000 to Operate with a MIC7000 Camera
VIDEOJET connect 7000
2014.10 | 1.4 | F.01U.291.524
Operation Manual
Bosch Security Systems