background image

10

en | Connection

VIP X1 XF E

F.01U.269.645 | V2 | 2012.06

Quick Installation Guide

Bosch Sicherheitssysteme GmbH

5

Connection

5.1

Connecting the camera and audio

Connect the camera to the socket 

VIDEO IN

.

Use the 

LINE IN/OUT

 socket for audio line connections.

CAUTION! 

Please observe the following specifications:

Line In

: 9 kOhm typ., 5.5 Vp-p max.

Line Out

: 16 Ohm min., 3 Vp-p max.

Summary of Contents for VIP-X1XF-E

Page 1: ...VIP X1 XF E VIP X1XF E en Quick Installation Guide ...

Page 2: ......

Page 3: ... Parts included 5 3 Unpacking 6 4 Installation 7 4 1 Preparing for wall mounting 7 4 2 Mounting the frame 8 4 3 Placing the unit in the frame 9 5 Connection 10 5 1 Connecting the camera and audio 10 5 2 Creating a serial connection 11 5 3 Alarm and relay connections 12 5 4 Establishing the network connection 13 5 5 Connecting the power supply 14 6 Assigning an IP address 15 ...

Page 4: ...VIP X1 XF E This Quick Installation Guide the Installation and Operating Manual and the current firmware package are available in various languages at www boschsecurity com WARNING You should always make yourself familiar with the required safety measures see Safety document enclosed Only operate the VIP X1 XF E in combination with an LPS NEC Class 2 power supply unit with limited output This Quic...

Page 5: ...ssysteme GmbH Quick Installation Guide F 01U 269 645 V2 2012 06 2 Parts included 1 VIP X1 XF E network video server 1 terminal block 4 self adhesive elastic bumpers 1 wall mounting panel 2 screws 2 wall plugs 1 Quick Installation Guide 1 Safety Hints ...

Page 6: ...U 269 645 V2 2012 06 Quick Installation Guide Bosch Sicherheitssysteme GmbH 3 Unpacking Check that the delivery is complete and in perfect condition Arrange for the unit to be checked by Bosch Security Systems if you find any damage ...

Page 7: ...ou can secure the VIP X1 XF E to any load bearing wall using the wall mounting panel in either a vertical or a horizontal position CAUTION If mounting the unit in a vertical position you will need to use the lower plastic frame and then place the unit onto the frame from above If mounting the unit in a horizontal position you can use either of the two frames ...

Page 8: ...ic frame on one side of the housing and carefully remove it from the unit Screw the plastic frame in the required position together with the wall mounting panel Check that the plastic frame is secure CAUTION The mounting location must be able to reliably hold the unit The load bearing capacity must be adequate for four times the weight of the unit ...

Page 9: ... 4 3 Placing the unit in the frame Place the unit on the wall mounting panel with the panel positioned between the housing and the second plastic frame Slide the unit into the plastic frame until you feel it lock securely into place Finally check that the unit is securely attached in the installation location ...

Page 10: ...h Sicherheitssysteme GmbH 5 Connection 5 1 Connecting the camera and audio Connect the camera to the socket VIDEO IN Use the LINE IN OUT socket for audio line connections CAUTION Please observe the following specifications Line In 9 kOhm typ 5 5 Vp p max Line Out 16 Ohm min 3 Vp p max ...

Page 11: ...ction If you require a serial connection to the VIP X1 XF E connect the relevant cables to the terminal block Connect the terminal block to the orange socket on the VIP X1 XF E IN GND 12V DC R R CTS RTS RXD TXD GND GND ACT LINK ETH V I P X 1 X F CTS RTS RXD TXD CAUTION Please observe the labeling on the orange socket of the VIP X1 XF E ...

Page 12: ...alarm switch to the appropriate terminals Connect the switch connection to the appropriate terminals IN GND 12V DC R R CTS RTS RXD TXD GND GND ACT LINK ETH V I P X 1 X F Alarm In IN GND R R CAUTION Please observe the labeling on the orange socket of the VIP X1 XF E Please observe the following specifications for the relay contact max 30 Vp p SELV 200 mA ...

Page 13: ...tssysteme GmbH Quick Installation Guide F 01U 269 645 V2 2012 06 5 4 Establishing the network connection Connect the VIP X1 XF E to the network via the ETH socket IN GND 12V DC R R CTS RTS RXD TXD GND GND ACT LINK ETH V I P X 1 X F UTP Cat 5 RJ45 ...

Page 14: ...the 12V DC socket The jack must fit a pin of 2 mm in diameter Insert the power supply unit plug into a suitable socket IN GND 12V DC R R CTS RTS RXD TXD GND GND ACT LINK ETH V I P X 1 X F CAUTION Only operate the VIP X1 XF E in combination with an LPS NEC Class 2 power supply unit that has limited output and meets the following specifications 12 V output voltage 0 30 A max ...

Page 15: ...t Video Client Click to start Configuration Manager The system automatically searches the network for compatible units When the unit is displayed in the list Configuration Wizard starts automatically If not select Configuration Wizard from the Tools menu Follow the instructions given in the Configuration Wizard window NOTICE Before you can operate the unit within your network it must have a valid ...

Page 16: ...16 en Assigning an IP address VIP X1 XF E F 01U 269 645 V2 2012 06 Quick Installation Guide Bosch Sicherheitssysteme GmbH ...

Page 17: ......

Page 18: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2012 ...

Reviews: