Technical Data
4.1
Specifications
Specification
Value
Power requirements
100 VAC - 240 VAC (90 VAC - 264 VAC with tolerance
considered), 50/60 Hz; 56V output
Alarm inputs *
Four (4) normal dry contacts (selectable N.O./N.C.)
Monitored supervised alarm input (Alarm 1), 2.2K ohm
(Ω) end-of-line terminating resistor
Alarm outputs *
Three (3) open collector outputs, 32 VDC, 150 mA
Audio *
One (1) mono line in; one (1) mono line out
connector 3.5 mm stereo jack
signal line in 9 kohm typical, 5.5 Vpp max. 25
signal line out 3.0 Vpp at 10 kohm typical;
2.3 Vpp at 32 ohm typical;
1.7 Vpp at 16 ohm typical
Washer driver output *
Dry contact relay, 250 V, 5 A
Washer switch *
Push button to activate/test the washer relay
momentarily
Communication
Three (3) 10BASE-T/100BASE-TX/1000Base-TX.
If SFP fiber optic modules installed: two (2) 1000 BASE-
FX
Local storage
One (1) slot for an optional CompactFlash (CF) memory
card, Type I / Type II, True IDE Mode, 1 TB max (user-
supplied)
SFP (small form-factor pluggable) Two (2) slots for use with SFP-based fiber optic modules
(1 GB only) as recommended in the section
Ingress Protection Rating/
Standard
IP66, IP67, NEMA Type 4
* Note
: This feature is valid only for a MIC7000 camera "bound" to Camera 1.
Notice!
If a MIC7000 camera is assigned to Camera 1 in the Transcoder Setup, it becomes “bound” to
the alarm inputs/outputs, the audio input/output, and the washer output provided by the
VIDEOJET connect 7000 device.