The settings on these pages are used to integrate the device into a network. Some changes
only take effect after a reboot. In this case
Set
changes to
Set and Reboot
.
1.
Make the desired changes.
2.
Click
Set and Reboot
.
The device is rebooted and the changed settings are activated.
12.1
Network Access
The settings on this page are used to integrate the camera into an existing network.
Some changes only take effect after the unit is rebooted. In this case, the
Set
button changes
to
Set and Reboot
.
1.
Make the desired changes.
2.
Click the
Set and Reboot
button. The camera reboots and the changed settings are
activated.
If the IP address, subnet mask, or gateway address is changed, then the device is only
available under the new addresses after the reboot.
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the camera.
Certain applications (Bosch Video Management System, Archive Player, Configuration
Manager) use the IP address for the unique assignment of the unit. If you use these
applications, the DHCP server must support the fixed assignment between IP address and
MAC address, and must be appropriately set up so that, once an IP address is assigned, it is
retained each time the system is rebooted.
IPv4
Fill in the 3 fields in this section of the screen.
IP address
Enter the desired IP address for the camera in this field. The IP address must be valid for the
network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (
0.0.0.0
).
IPv6
Consult with the network administrator before making changes to this section.
IP address
Enter the desired IP address for the camera in this field. The IP address must be valid for the
network. A typical IPv6 address may resemble the following example:
2001:db8: :52:1:1
Consult the network administrator for valid IPv6 address construction.
Prefix length
A typical IPv6 node address consists of a prefix and an interface identifier (total 128 bits). The
prefix is the part of the address where the bits have fixed values or are the bits that define a
subnet.