Videojet connect 7000
Troubleshooting and Maintenance | en
53
Bosch Security Systems
Installation Manual
2019-08 | 1.7 | F.01U.291.524
16
Troubleshooting and Maintenance
16.1
Troubleshooting
(1)
(1)
(2)
(2)
(3)
1
Figure
16.1: LEDs in VIDEOJET connect 7000
The table below identifies the behavior of the LEDs on the PCBA.
LED
Symbol
Function
Color/Behavior
1
D100
Power
Off: Power not applied
Red: Startup in progress
Green: Power/Unit is active
Red flashing: System fault (for example, FW upload failed)
2
P3V3
Reserved
Factory use only.
Orange: Power is applied
3
D1301
CF Recording
Off: CF not installed or not recording
Orange: Recording active
4/5
D403/
D404
SFP1/
SFP2
Off: SFP not installed or not connected to a network
Green: SFP installed and connected to a network
Green flashing: Network traffic
6-8
D400/
D402/
D405
ETH1/
ETH2/
POE
Off: Not connected to a network / faulty cable
Green: Connected to a network
Green flashing: Network traffic
16.2
Maintenance
Damage requiring service
– Unplug the devices from the main AC power source and refer
servicing to qualified service personnel whenever any damage to the device has occurred,
such as:
- the power supply cable is damaged;
- an object has fallen on the device;
- the device has been dropped, or its enclosure has been damaged;
- the device does not operate normally when the user follows the operating instructions
correctly.
Servicing -
Do not attempt to service this device yourself. Refer all servicing to qualified
service personnel.
Summary of Contents for VJC-7000-90
Page 1: ...Videojet connect 7000 VJC 7000 90 en Installation Manual ...
Page 2: ......
Page 57: ......