64
VPV Vane Pump
VPV 100/130/164 to VPV 16 S.A.E. & Metric Combination
,
y
,
y
,
y
z
,
y
z
IN
OUT
z
,
y
IN
OUT
,
y
0.70
(18.0)
2.08
(52.9)
1.85
(46.9)
45
°
12.80
(325.0)
12.80
(325.0)
ø7.87
(ø200.0)
ø1.57
(ø40.0)
.47 square key
(12.0)
.44 square key
(11.1)
.81
(20.7)
ø1.75
(ø44.42)
S.A.E. “D” 2-bolt
mounting flange
per ISO 3019/1
9.00
(229.0)
7.65
(194.2)
16.08
(408.5)
16.08
(408.5)
7.27
(184.7)
7.65
(194.2)
7.27
(184.7)
1.94
(49.3)
2.08
(52.9)
12.11
(307.6)
6.06
(153.8)
5.76
(146.2)
19.17
(486.8)
17.26
(438.5)
20.63
(524.1)
7.44
(189.0)
3.44
(87.5)
2.81
(71.3)
2.81
(71.3)
5.77
(146.6)
4.72
(120.0)
12.87
(326.9)
15.99
(484.4)
18.51
(470.1)
ø.69 thru support hole
(ø17.5)
Case drain
“SAE” #8 S.A.E.
“METRIC” 3/8-19 BSPP
Case drain
“SAE” #8 S.A.E.
“METRIC” 3/8-19 BSPP
2.24
(57.0) 0.96
(24.4)
Inlet port
Std. S.A.E. 2 1/2” pad
ø2.47 typ
(ø62.7)
Inlet port
“SAE” #16 S.A.E.
“METRIC” 1-11 BSPP
3.93
(111.6)
3.50
(88.9)
1.75
(44.5)
2.00
(50.8)
1.00
(25.4)
“SAE” 1/2-13UNC-2B TH’D X 1.10 deep
“METRIC” M12 X 1.75-6H TH’D (28.0)
Support point
“SAE” 3/8”-16UNC-2B TH’D
X
.59
deep
“METRIC” M10 X 1.5 TH’D (15.0)
Compensator adjusting knob
(CW rotation increases
pressure setting)
DETAIL
SAE-SAE
DETAIL
METRIC-METRIC
SAE/METRIC
SAE/METRIC
A
B
A
B
(SH.2 2 K-6)
(SH.2 @ C-6)
T
METRIC 4-bolt
mounting flange
per ISO 3019/2
Inches (millimeters)