Cleaning and maintenance
en
25
Detergent solution pump
blocked
:
Warning
Risk of scalding!
When you wash at high temperatures,
the water gets very hot. If you come into
contact with the hot water, you may be
scalded.
Allow the water to cool down.
1.
Turn off the water tap so that no
more water can flow in and has to be
drained via the drain pump.
2.
Switch off the appliance. Disconnect
the mains plug.
3.
Open and remove the service flap.
4.
Take the drain hose out of the
retainer.
Remove the sealing cap, allow the
detergent solution to flow out into a
suitable container.
Replace the sealing cap and place
the drainage hose in the retainer.
5.
Carefully unscrew the pump cover,
residual water may leak out.
Clean the interior, pump cover
thread and pump housing. The
impeller in the detergent solution
pump must be able to rotate.
Refit the pump cover and screw it on
tightly. The handle must be in a
vertical position.