36
4.
Take the drainage hose out of the holder. Remove the
sealing cap, drain water into a suitable receptacle.
Press on sealing cap and insert drainage hose into the
holder.
Note:
Residual water may run out.
5.
Carefully unscrew the pump cover. Clean the interior, pump
cover thread and pump housing (fan impeller in the
detergent-solution pump must rotate).
6.
Reinsert and screw on pump cover. Handle should be
vertical.
7.
Insert service flap (1), engage (2) and close (3).
²
To prevent unused detergent from flowing into the outlet during
the next wash cycle: Pour approx. 1 litre of water into dispenser
II
and start the
Drain
programme.
Drainage hose on the siphon blocked
1.
Switch off the appliance. Pull out the mains plug!
Note:
Residual water may run out!
2.
Loosen hose clip, carefully remove drainage hose.
3.
Clean drainage hose and siphon spigot.
4.
Re-attach drainage hose and secure connection point with
hose clip.