en
Faults and what to do about them
56
3.
4.
Pull the emergency release
downwards with a tool and release.
The door can then be opened.
Information on the display panel
Display
Cause/Remedy
œ
■
Flashes fast + signal
: The door was opened and the water level is too high.
Close the door, continue the programme with
A
button or select
0
pro-
gramme.
■
Flashes slowly
: The door lock temperature is too high to open the door. Wait
approx. 30 seconds until the door lock temperature cools down.
Hot
The door cannot be opened after the drying programme due to the high tempera-
ture. The cooling process continues until the display disappears, after which the
door can be opened.
r
■
Flashes
(no water supply): Water tap turned on? Filter in the water supply is
blocked?
"Filter in the water supply is blocked" on page 54
Is the supply hose kinked or trapped?
■
Lights up
(low water pressure): For information only. This will not affect the
programme progress. The programme duration is extended.
E:3
0
alternating with
-
8
0
■
Drain pipe or water drain hose is blocked. Clean the drain pipe and the water
outlet hose.
■
Drain pipe or water drain hose is caught or jammed. Ensure that the drain pipe
and water drain hose are not kinked or trapped.
■
The drain pump is blocked.
"Drain pump is blocked" on page 53
■
The drain hose at the siphon is blocked.
"The drain hose at the siphon is blocked" on page 54
■
The water drain hose is connected too high. Install the water outlet hose at a
maximum height of 1 meter.
"Hose and cable lengths" on page 16
E:35
alternating with
-10
(Suitable for spe-
cial models)
There is water in the base trough, the appliance is leaking. Turn off the tap. Call
customer services.
H:95
alternating with
End
when programme is
finished
No water detected in drying phase, may get bad drying result.