Troubleshooting
en
49
Fault
Cause
troubleshooting
"E:10 / -10"
The tap is turned off.
▶
Turn on the tap.
The water inlet hose is
kinked or jammed.
▶
Ensure that the water inlet hose is
not kinked or jammed.
flashes.
The automatic voltage con-
trol system detects an unau-
thorised voltage under-us-
age.
▶
No remedial action possible.
Note:
If the power supply is stable, the
programme continues to run as nor-
mal.
flashes.
Voltage under-usage causes
a programme extension.
No remedial action possible.
All other error codes.
Malfunction
▶
Call the after-sales service.
Malfunctions
Fault
Cause
troubleshooting
The appliance is not work-
ing.
The mains plug of the power
cord is not plugged in.
▶
Connect the appliance to the power
supply.
The circuit breaker is faulty.
▶
Check the circuit breaker in the
fuse box.
There has been a power cut.
▶
Check whether the lighting in your
kitchen or other appliances are
working.
The programme does not
start.
You have not pressed
Start /
Reload
.
▶
Press
Start / Reload
.
Door is not closed.
1.
Close the door.
2.
Press
Start / Reload
to start the
programme.
Childproof lock is activated.
▶
Ready In
is activated.
▶
Check whether
Ready In
is activ-
ated.
Laundry is caught in the
door.
1.
Open the door again.
2.
Remove any trapped laundry.
3.
Close the door.
4.
Press
Start / Reload
to start the
programme.