en
Cleaning and maintenance
44
3.
Take the drain hose out of the
retainer.
Remove the sealing cap and pour
the water out into a suitable
container.
Replace the sealing cap and place
the drain hose back in the retainer.
4.
Carefully unscrew the pump cover;
residual water may leak out.
Clean the interior, pump cover
thread and pump housing. The
impeller in the drain pump must be
able to rotate.
5.
Refit and screw on the pump cover.
The handle must be in a vertical
position.
6.
Close the service flap.
Note:
To prevent unused detergent
from flowing straight into the drain
during the next wash: Pour 1 litre of
water into Dispenser II and start the
[
(Drain)
programme.
The drain hose at the siphon
is blocked
1.
Turn the programme selector to
Û
(Off)
. Pull out the mains plug.
2.
Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
3.
Clean the drain hose and siphon
connecting piece.
4.
Re-attach the drain hose and secure
the connection point using the hose
clamp.