Fig. 9. Central heating by-pass adjustment
9
Filling Loop
Filling Key
Filling Knob
NOTE:
Always remove
the filling key
after filling
Fig. 8. Filling Loop.
Fig. 8a. Filling Key inserted for filling.
Fig. 7. System layout if using twin zone valves (S) plan.
Central Heating
System By-Pass
Adjustment Screw
Use Flat Bladed
Screwdriver to
make adjustment.
RV
LV
LV
RV
RV
RV
LV
LV
INDIRECT
CYLINDER
APPLIANCE
Refer to fig.1.
Appliance
Water
Flow
Diagram
Heating Return
Heating Flow
Safety Discharge
Cylinder Return
Hot W
ater Flow
BS
Stop Valve Fixed Cylinder Type
Mains Cold Water
Radiator Valve - Flow
RV
Lockshield Valve - Return LV
Note:
A drain cock
should be fitted
at the lowest
point of the
heating circuit
and beneath
the appliance
CH
Zone
Valve
DHW Zone Valve
IMPORTANT
For Details of
the wiring
requirements
for the system
controls,
please refer to
the SBi system
wiring guide.