Before installation
6 720 613 057 (2006/04)
12
4.2.2 Pipework connections
For the pipework connection a connection kit and a con-
nection set between the collectors will be required.
Connection kit, per collector array (Fig. 3)
Connection set between the collectors, for each
collector (in two corner protectors, Fig. 4)
Fig. 3
Connection kit and connection set (illustration shows 2 portrait collectors)
63043966.03-1.SD
63043966.03-1.SD
2
1
3
4
7
6
5
Item 2:
Pipe clip
2
×
Item 6:
Size 5 spanner
1
×
Item 3:
Connecting pipe (insulation not shown)
2
×
Item 7:
End cap
2
×
Item 4:
Insulation for corrugated pipe
Item 8:
Sensor bush plug, not shown
1
×
connector 710 mm
1
×
Item 5:
Fitting for collector sensor
1
×
Fig. 4
Two corner protectors with one connection set
63043966.04-1.SD
63043966.04-1.SD
1
2
Item 1:
Corrugated pipe connector
2
×
Item 2:
Pipe clip
4
×
Summary of Contents for Worcester FKT Series