Appliance information
6 720 808 928 (2017/06)
11
Control unit connections
Component connections
Installer connections
Connections/
Symbol
Function
Circulation pump
• Live output [Brown]
• Neutral output [Blue]
• Earth output [Green/Yellow]
Flow turbine connection
• Red [4]
• -
• Yellow [2]
• Black [1]
Flow sensor NTC (district heating)
• White [2]
• White [1]
Domestic Hot Water sensor NTC
• Blue [2]
• Blue [1]
Central heating control valve
• Brown [4]
• Black [3]
• White [2]
• Yellow [1]
Domestic Hot Water control valve
• Blue [4]
• Green [3]
• Grey [2]
• Red [1]
Flow sensor NTC (central heating)
• Yellow [2]
• Yellow [1]
Return sensor NTC (district heating)
• Green [2]
• Green [1]
Not used
Control panel fuse
Table 3
63
N
4
3
2
1
2
1
2
1
4
3
2
1
4
3
2
1
2
1
2
1
2
1
Connections/
Symbol
Function
Limiter thermostat (under-floor safety cut-off)
• Potential free
230 V feed to external controls modules
• Live output [L]
• Neutral output [N]
• Earth output [
]
230 V supply to the appliance
• Live input [L]
• Neutral input [N]
• Earth input [
]
Not used
Sense II connection
• Not polarity sensitive
Outdoor temperature sensor
• Not polarity sensitive
Not used
230 V feed to external time and temperature
control
• Switch live demand input [LR]
• Live output [L]
• Neutral output [N]
• Earth output [
]
Not used
Not used
Table 4
LR
L
230V
OUT
L
N
L
N
230V
IN
2
1
BUS
EMS
2
1
2
1
PW2
14
N
LR
L
120/230 VAC
N
PW1
14
N
2
1
Summary of Contents for Worcester Greenstar HIU