Oil appliance commissioning checklist
This Commissioning checklist is to be completed in full by the competent
person who commissioned the appliance as a means of demonstrating
compliance with the appropriate Building Regulations and then handed
to the customer to keep for future reference.
IMPORTANT
▶ Leave this manual with the Homeowner or at the
appliance.
Appliance details
Appliance make and model:
Appliance serial number:
Commissioning Engineer
Commissioning checks
Company name:
Oil type used is Kerosene
Yes
Company address:
Pump pressure
Bar/psi
CO
2
%
CO
ppm
CO/CO
2
ratio
Telephone number:
Smoke reading
Commissioned by
(signature)
Flue gas temperature
°C
(print name)
Flue pressure
Commissioning date:
Burner model:
Controls: Tick the appropriate boxes
Time and temperature control to heating
Room thermostat and programmer/timer
Programmable room thermostat
Load/Weather compensation
Optimum start control
Time and temperature control hot water
Cylinder thermostat and programmer/timer
Combination boiler
Heating zone valves
Fitted
Not required
Hot water zone valves
Fitted
Not required
Thermostatic radiator valves
Fitted
Not required
Automatic by-pass valve fitted to system
Fitted
Not required
Boiler interlock
Provided
All Systems
The system has been flushed and cleaned in accordance with BS7593 and appliance manufacturer’s instructions?
Yes
What system cleaner was used?
What inhibitor was used?
Quantity
litres
Has a system filter been fitted?
Yes
No
The condensate drain has been installed in accordance with the manufacturer’s instructions and/or BS5410?
Yes
If the condensate pipe terminates externally has the pipe diameter been increased and weatherproof insulation fitted?
Yes
Central Heating mode: Measure and record
Central Heating flow temperature
°C
Central Heating return temperature
°C
Combination boilers only
Domestic Hot Water mode: Measure and record
Is the installation in a hard water area (above 200ppm)?
Yes
No
If yes, has a water scale reducer been fitted?
Yes
No
What type of scale reducer has been fitted?
Cold Water Inlet temperature
°C
Hot Water Outlet temperature
°C
Water flow rate
l/min
All installations
Fire valve fitted rated to 85 °C.
Yes
Is the oil tank and supply clean and free from contamination?
Yes
No
If required, is the flue damper correctly fitted?
Yes
No
Are the hoses from the air pressure switch correctly routed and free from kinking?
Yes
No
Is a solid non-combustible surface large enough to accommodate the appliance provided?
Yes
No
Does the installation comply with current OFTEC Regulation?
Yes
No
The heating and hot water system complies with the appropriate Building Regulations?
Yes
No
The appliance and associated products have been installed and commissioned in accordance with the manufacturer’s instructions? Yes
No
The operation of the appliance and system controls have been demonstrated to and understood by the customer?
Yes
No