Appliance information
Greenstar Utility
ErP -
6 720 821 751 (2018/04)
6
3
Appliance information
3.1
General information
Standard package
1 - Floor standing oil fired condensing appliance
2 - Literature pack:
• Greenstar Utility Installation, Commissioning and Servicing
instruction manual
• User Instructions
• Guarantee registration card
3 - ErP label
Fig. 1
[A]
1098mm
[B]
795mm
[C]
598mm
3.2
Technical data
A
C
B
67208
21751-03.1W
o
2
1
3
Description
Units
32/50 50/70
Central heating
Primary water capacity (total)
litres
50
51
Maximum static head
metres
30
30
Minimum static head
metres
1
1
Water side resistance (20°C difference)
mbar
24
45
Flue
Exit flue gas mass flow
kg/hr
76
106
Conventional flue (min. diameter required)
mm
130
130
Room sealed flue (diameter)
mm
100/
150
100/
150
Pipework connections
Fuel line (compression)
mm
10
10
CH flow
inch BSP
1¼
1¼
CH return
mm
28
28
CH vent
inch BSP
1¼
1¼
Condensate (polypropylene)
mm
21.5
21.5
Electrical
Electrical power supply voltage
AC. .
.V
230
230
Frequency
Hz
50
50
Thermostats
Appliance flow temperature range (cut out)
°C
50/80 50/80
CH control thermostat differential
°C
5
5
Appliance high limit thermostat set point
(+ 0 / - 6°C)
°C
95
95
Appliance manual reset overheat
thermostat (cut out)
°C
105
105
Flue manual reset overheat thermostat
(+ 0 / - 6°C)
°C
110
110
General data
Maximum hearth temperature
°C
< 85
< 85
SEDBUK 2005 (Band A)
%
93.0
92.5
SEDBUK (2009)
%
90.7
90.5
Appliance protection rating
IP
20
20
Weight (excluding packaging)
kg
215
220