en
Cleaning and maintenance
30
Filter in the water inlet hose
blocked
:
Warning
Danger of death!
Do not immerse Aqua-Stop safety
device in water (contains an electric
valve).
First, reduce the water pressure in the
supply hose:
1.
Turn off the tap.
2.
Select any programme (except
0
(
Spin
)/
[
(
Empty
)).
3.
Select
Inicio
/Pausa+Carga (
Start
/
Reload). Allow the programme to run
for approx. 40 s.
4.
Turn the programme selector to
Ú
Stop
(
Off
). Pull out the mains plug.
5.
Clean the filter on the tap:
Disconnect the hose from the water
tap.
Clean the filter with a small brush.
6.
Clean the filter on the back of the
appliance (for Standard and Aqua-
Secure):
Remove the hose from the rear of
the appliance.
Take out the filter with pliers and
clean it.
7.
Connect the hose and check for
leaks.
Air filter blocked
1.
Turn the programme selector to
Ú
Off
. Pull out the mains plug.
2.
Open and remove the service flap.
3.
Take out the air filter.
4.
Rinse fluff off the air filter using
a brush under running water.
5.
Re-insert the air filter.
6.
Re-insert and close the service flap.