8
en | Safety
Integrated IR Dome Camera
TBD | 2.0 | 2010.12
Installation Manual
Bosch Security Systems, Inc.
Electronic Surveillance -
This device is intended for use in
public areas only. U.S. federal law strictly prohibits
surreptitious recording of oral communications.
Environmental statement -
Bosch has a strong commitment
towards the environment. This unit has been designed to
respect the environment as much as possible.
Electrostatic-sensitive device -
Use proper CMOS/MOS-FET
handling precautions to avoid electrostatic discharge.
NOTE: Wear required grounded wrist straps and observe proper
ESD safety precautions when handling the electrostatic-
sensitive printed circuit boards.
Fuse rating -
For protection of the device, the branch circuit
protection must be secured with a maximum fuse rating of 16A.
This must be in accordance with
NEC800 (CEC Section 60)
.
Outdoor signals -
The installation for outdoor signals, especially
regarding clearance from power and lightning conductors and
transient protection, must be in accordance with
NEC725
and
NEC800 (CEC Rule 16-224
and
CEC Section 60)
.
Permanently connected equipment -
Incorporate a readily
accessible disconnect device external to the equipment.
Pluggable equipment -
Install the socket outlet near the
equipment so it is easily accessible.
Power resupply -
If the unit is forced to power down due to
exceeding the specified operating temperatures, disconnect
the power cord, wait for at least 30 seconds, and then
reconnect the power cord.
Power lines -
Do not locate the camera near overhead power
lines, power circuits, or electrical lights, nor where it may
contact such power lines, circuits, or lights.
SELV -
All the input/output ports are Safety Extra Low Voltage
(SELV) circuits. SELV circuits should only be connected to
other SELV circuits.
Because the ISDN circuits are treated like telephone-network
voltage, avoid connecting the SELV circuit to the Telephone
Network Voltage (TNV) circuits.
System ground/Safety ground