background image

English 

 3

PRO.BOSE.COM

Design Guide Supplement: Safety Cables

Design Requirements When Using the Safety Cable

If the loudspeaker requires a safety cable, please note the following information to aid your 

design process:

The safety cable must be wrapped securely around a building support structure. For 

surface-mount loudspeakers, you may wrap the safety cable securely around a structural 

attachment point, such as an eye screw above the loudspeaker, as an alternative.

After attaching the safety cable to both the loudspeaker and building support structure 

(or attachment point), you must remove enough slack from the safety cable such that, 

in the event of a fall, the top (rear) of the loudspeaker will drop to a distance of no more 

than 

152 millimeters (6 inches)

 below the ceiling (if it is a flush-mount loudspeaker, Fig. 

A) or from its mounted location (if it is a surface-mount loudspeaker, Fig. B) before it is 

retained by the safety cable.

Refer to the safety cable installation guide for detailed instructions and important safety 

warnings when installing the safety cable.

Safety Cable Ordering & Specifications

When you purchase any of the affected products from Bose, a safety cable will be provided for each loudspeaker. To obtain 

safety cables for loudspeakers that are already installed, visit 

BoseBMSSafety.com

.

Bose can provide these two types of safety cable kits for free:

Kit

Compatible Products

Part Number

Specifications

Flush-mount 

safety cable kit

EdgeMax EM90
EdgeMax EM180
FreeSpace DS 16F
FreeSpace DS 40F
FreeSpace DS 100F
FreeSpace 3 Flush-Mount Satellites

839760-0010

Length:

 6.1 m (20.0 ft)

Ends:

 1 closed-loop end,  

1 open end with fastener

Surface-mount 

safety cable kit

FreeSpace DS 16S / 16SE
FreeSpace DS 40SE
FreeSpace DS 100SE
FreeSpace 3 Series II Acoustimass module*

839761-0010

Length:

 1.5 m (5.0 ft)

Ends:

 1 end with 90° eyelet,  

1 open end with fastener

*

 The FreeSpace 3 Series II Acoustimass module requires the surface-mount safety cable kit as this model does not have attachment 

points for the flush-mount safety cable.

If the safety cable provided by Bose is too short, you may substitute a longer safety cable only if it meets the specifications 

listed below. Failure to meet these requirements could cause the loudspeaker to fall and result in personal injury or 

property damage.

Material:

 Galvanized high-tensile steel to EN12385

Cable Diameter:

 2 mm (5/64 in)

Strand Configuration:

 7 × 7

If you are unable to install the Bose-provided cable 

or

 a longer substitute that meets the requirements that Bose has 

provided, do not install the loudspeaker and return it to Bose for a refund. (This applies only to loudspeakers installed in 

commercial cooking environments.)