24
BoSS Clima 3T
Instruction Manual
•
Beware of high winds. This tower has been assessed
as a freestanding structure for wind loads equating
to 27mph (43kph, 12m/s). If greater windspeeds are
forecast the tower must be moved to a sheltered
location or dismantled while it is still safe to do so.
•
Sheets, tarpaulins, or signage must not be attached to this tower outdoors.
•
Towers above 8.2m platform height are for indoor use only.
3.4
Movement Of The Assembled Prefabricated Tower
Scaffold
MOVING A FULLY ASSEMBLED TOWER CAN BE EXTREMELY
HAZARDOUS.
If there is any doubt about the safety of the move, the tower must be dismantled and
reassembled in the new location.
This tower is not designed to be lifted or suspended.
Ensure gloves or other suitable hand protection is worn.
Before
•
Beware of rough, sloping ground and high winds.
Tower stability is improved by reducing height.
•
Survey the route to be taken. Assess the ground
condition/slope and any overhead obstructions or
hazards and wind conditions.
27mph
12m/sec
3
Using The Tower