background image

11

LED check

Green

Improve the

feeder

system

Strong interference near donor

antenna

Abnormal

Feeder system

inspection

Improve the

power supply

system

Red

Off

Isolation

inspection

Power supply

inspection

Abnormal performance

Abnormal

Abnormal

Abnormal

Chapter 6 Product Maintenance

6.1 Operation and maintenance

Power supply

Please make sure the voltage and frequency comply with the repeater requirement.

Component replacement

Please do not maintain or replace components by yourself, otherwise may get an

electric shock. Only the authorized professional can maintain and replace the
components.

Waterproof and moist proof

Please do not turn on or off the booster in moist environment when its door is

opened.

6.2 Emergency dealing

Switch off is recommended during following situations:

The power supply is not normal

Liquid flows into the equipment;

Working conditions is not normal, (overheating, abnormal smelling, abnormal sundries)

Closet damage

performance debasement

near to fire

flooding

6.3 Maintaining direction

Please check the repeater step by step according to below process, to find out the problem

with the repeater.

Contact supplier

Summary of Contents for BOSSGSM-LED-HP27D

Page 1: ...1 Triband signal repeater User Manual ...

Page 2: ...m dia gra m 5 3 4 Appearance Diagram 5 3 5 Po rt s 5 Chapter 4 Installation 6 4 1 Installation requirements 7 4 2 In stalla tion 7 4 3 Connec tion 7 Chapter 5 Repeater setting 8 5 1 Power supply connection 8 5 2 Performance setting 9 Chapter 6 Product Maintenance 10 6 1 Operation and maintenance 10 6 2 Emergency dealing 10 6 3 Maintaining directions 11 ...

Page 3: ... Only the professional can operate electrified 3 Do not dismantle machine maintain or displace accessories by yourself because in this way the equipment may be damaged or even get an electric shock 4 Do not open the repeater touch the module of repeater even not to open the cover of module to touch the electronic component the components will be damaged due to electrostatic 5 Please keep away from...

Page 4: ...atly with its integrated design compact size easy engineering and rapid installation and debugging Chapter 3 Specs and features 3 1 Product Descriptions 1 In Terminal N Female 2 LED To monitor the status of power on off and normal operation 3 Power Supply Terminal External 4 Power supply Operating voltage 9V 5A 3 2 Features Compact design and light weight cost effectiveness LED indication for oper...

Page 5: ...o limit output power at specified power level and ensure stable coverage effect AGC function by 1dB step from 1 31dB Gain range 3 3 System diagram 3 4 Appearance Diagram 3 5 Ports BTS for outdoor MS for indoor Chapter 4 Installation ...

Page 6: ...ction Install in the place that is not easy to be reached by irrelevant people Install at the place that is convenient for power supply and cabling Avoid heat source and moist environment Power supply requirement AC power supply of AC 95 264V Installation tools and accessories Series item specification Quantity Remarks 1 Expanding plug M7 4 Accessories 2 Tapping screw M6 40 4 Accessories 3 Spinner...

Page 7: ...ort connect with the outdoor antenna put antenna on the place where there is strong signal then connect to MS port of equipment and assure good connection Grounding connection Use earth wire to link the repeater grounding port with building grounding system Power resistance must be less than 10 Ohm Power supply connection Please use three pin plug to assure good grounding Chapter 5 Repeater settin...

Page 8: ...ce setting Status Definition green Normal off DC power problem Status Definition of ALARM Green Meaning working well Red Meaning self oscillation strong input signals Attention Please adjust LED Panel Red Meaning overloading or self oscillation strong input signals Red Attention input signal level is too high or the space of donor antenna and service antenna is not enough please adjust the dB If t...

Page 9: ...age effect are stable But from another point of view we hope the equipment is as far as possible away from overloading status of red thus the equipment would hold higher interference depression ability So we try our best to set the equipment near edge point when engineering Setting of edge point Switch on the power supply after connection with donor antenna and coverage antenna and observe ALARM i...

Page 10: ...led which can be activated via the front panel users can adjust gain and choose working band by LED panel It is a simple safe and effective way When the repeater turn on will show green can choose Sys 1 or Sys 2 for uplink for downlink add and subtract dB you can see accurate gain from this LED 5 3 Auto Level Control The 30dB ALC is used to maintain steady output power even when the donor source s...

Page 11: ...ents by yourself otherwise may get an electric shock Only the authorized professional can maintain and replace the components Waterproof and moist proof Please do not turn on or off the booster in moist environment when its door is opened 6 2 Emergency dealing Switch off is recommended during following situations The power supply is not normal Liquid flows into the equipment Working conditions is ...

Reviews: