background image

 

 

       

EA000405

 

 

B

OARDER 

R

OUTER 

 

 

1

 

 

 

 

 

 

EA000405 

Border Router 

 

I

NSTRUCTION 

M

ANUAL  

 

V

ERSION 

1.0 

Summary of Contents for EA000405

Page 1: ...EA000405 BOARDER ROUTER 1 EA000405 Border Router INSTRUCTION MANUAL VERSION 1 0 ...

Page 2: ...R 2 VISIT OUR WEBSITE FOR MORE INFORMATION WWW BOSSPAC COM BOSSPAC ENGINEERING TECHNOLOGY CALGARY HEAD OFFICE PHONE 403 216 1226 FAX 403 216 5557 E MAIL INFO BOSSPAC COM 1450 28 STREET NE BAY 8 CALGARY ALBERTA CANADA T2A 7W6 ...

Page 3: ...any device Commission a Border Router onto an existing network Joining a Border Router onto a network Required Tools Computer Run on Windows EA000405 Border Router 10 to 24V Power Supply 915 MHz Antenna Ethernet Cable o Physical connection to Personal Internet router 915 MHz Antenna DRC Gateway 12V Power Supply Ethernet cable ...

Page 4: ...f supplying up to 2A Unless otherwise specified the EA000405 Border Router ships with a 3 dBi antenna EA002058 The EA000405 Border Router is compatible with the following antennas BossPac PN Gain EH002058 Standard 3 dBi EH002059 1 2 dBi EH002060 8 dBi EH000625 11 dBi 2 Commissioning 2 1 Set up Power On Connect one end of the Ethernet cable to your ethernet router Connect the other end of the Ether...

Page 5: ...Command prompt On command prompt type ssh pi Border Router IP address If connecting to the border router for the first time command prompt will print Are you sure you want to continue connecting yes no Type on command prompt yes If the border has a password command prompt will ask you for a password in which then you type password and then press enter Command prompt will print pi ...

Page 6: ...press enter Command prompt will print On command prompt type Commissioner start then press enter Command prompt will print Done and Commissioner active On command prompt type commissioner joiner add 123456 then press enter Command prompt will print Done To close commissioner type on command prompt commissioner stop then press enter Command prompt will print Commissioner disabled and Done 2 3 3 Sta...

Page 7: ...cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le...

Page 8: ...EA000405 BOARDER ROUTER 8 For further Technical Assistance Email support bosspac com Or call 866 616 1226 or 403 216 1226 ...

Reviews: