23
MACHINE SET UP GASLESS MIG WELDING CONTINUED
DCEN - GASLESS
DCEP - GAS
SETTING MACHINE POLARITY
Fit the Earth lead Dinse Plug to the positive
terminal for gasless welding and then connect
earth clamp to the work piece ensuring that
the clamp makes good contact with bare
metal.
Ensure the polarity is correct for gasless
welding, DCEN
5
8
9
10
6
Re install tip and nozzle to torch and trim wire
to the end of the nozzle. The multifunction
digital display will show two numbers. On the
left is the wire speed, on the right is welding
voltage. These values are adjusted by
rotating the Welding Parameter Adjustment
Knobs below them.
Switch the machine on using the mains power
switch. Wait a few seconds whilst the machine
powers up
Remove nozzle and tip from torch and press
trigger on the welding torch, this will feed the
wire through the torch. Release button when
wire appears at the end of the torch.
Press the Welding Mode Selection Button until
the MIG indicator is lit.
7