Boste BK Series
15
Miscellaneous continued
Problem/
Report
Possible Cause
Suggested Action
Slow but Continuous Water Dispense
From
Ambient
or Cold Water
Valve
Low incoming Water
pressure.
Consider re-plumbing to alternative supply
if possible or boosting the inlet supply
pressure.
From Sparkling
Water Valve
Low/no CO
2
Pressure.
Check Regulator and/ or replace cylinder.
Intermittent Water Dispense
From
Ambient
or Cold Water
Valve
Trapped air in pipe work
(especially where water
pressure is low or after
filter change).
Hold button on to purge air out. (This could
take several minutes where pressure is low).
Use filter function if available.
Button Not being pressed
enough.
Press button firmly N.B. This could be
caused by a surrounding cold environment
making the action stiffer.
Faulty C o n t r o l PCB
Replace C o n t r o l PCB.
From Ambient
or Cold Water
Valve and
hammering
noise
Fluctuating mains water
pressure situation.
Contact Azure regarding special
replacement washers available.
Continuous Water Dispense
From Ambient/
Cold or
Sparkling
Water Valve.
Button jammed on/faulty.
Replace Control PCB and or/ button Panel as
needed.
Debris blocking hole in
diaphragm washer.
Dismantle Valve and clean out.
Faulty solenoid valve.
Check valve and replace if needed.
Summary of Contents for UDC102
Page 1: ...1 PRODUCT MANUAL Boste BK Series UDC102 Undersink Dispenser Model ...
Page 16: ...Boste BK Series 16 Diagrams Parts Lists ...
Page 17: ...17 ...
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ...Boste BK UDC102 ...
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......