10
drAin VAlVe
H
The drain valve (H) is located at the base of the air tank
and is used to drain condensation at the end of each use.
See
Draining Air Tank
under
Maintenance.
CoolinG sYstem (not shown)
This compressor contains an advanced design cooling
system. It is normal for this fan to blow air through the vent
holes in large amounts. The cooling system is working
when air is expelled.
Air Compressor pump
The pump compresses air into the air tank. Working air is not available until the compressor
has raised the air tank pressure above that required at the air outlet.
motor oVerloAd proteCtor (not shown)
J
L
K
This motor has a thermal overload protector. If the motor
overheats for any reason, the overload protector will shut
off the motor. The motor must be allowed to cool down
before restarting.
To restart:
1. Set the On/Off (A) lever to Off and unplug unit.
2. Allow the motor to cool.
3. Plug the power cord into the correct branch circuit receptacle.
4. Set the On/Off (A) lever to ON position.
oil dipstiCK
J
MAX
MIN
The oil dipstick (J) indicates the amount of oil in the
pump. Check pump oil daily, see
Compressor Pump
Oil
under
Maintenance.
Air intAKe filter
The filter (L) is designed to clean air entering the pump. To ensure the pump continually receives
a clean, cool, and dry air supply the filter must always be clean and the filter intake must be free
from obstructions.
INSTAllATION
ASSEMBlY
You must assemble the compressor before using it for the first time.
fittinG the wheels
• Fit the supplied wheels as shown in figures 5:
• Fig. 5a & 5b: Assembly of wheel kit. Tighten securely.
• Fig. 5c: Assembly of bumper
5b
5a
Axle Bolt
Axle Nut
Wheel
5c
Bumper
Wheel