background image

-3-

SAFETY INSTRUCTIONS

EYE PROTECTION which conforms to ANSI specifications and provides protection against
flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and
others in the work area when connecting to air supply, loading, operating or servicing this
tool. Eye protection is required to guard against flying fasteners and debris, which could
cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn.  Eye protection
equipment must conform to the requirements of the American National Standards Institute,
ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded
spectacles and face shields alone do not provide adequate protection.

CAUTION: Additional Safety Protection will be required in some environments. For
example, the working area may include exposure to noise level which can lead to hearing
damage. The employer and user must ensure that any necessary hearing protection is
provided and used by the operator and others in the work area. Some environments will
require the use of head protection equipment. When required, the employer and user must
ensure that head protection conforming to ANSI Z89.1 is used.

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as
tool may explode, possibly causing injury.

Do not use supply sources which can potentially exceed 200 P.S.I.G. as tool may burst,
possibly causing injury.

The connector on the tool must not hold pressure when air supply is disconnected.  If a
wrong fitting is used, the tool can remain charged with air after disconnecting and thus will
be able to drive a fastener even after the air line is disconnected possibly causing injury.

Do not pull trigger or depress contact arm while connected to the air supply as the tool may
cycle, possibly causing injury.

Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool;
3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work
area, as accidental actuation may occur, possibly causing injury.

LOADING TOOL

When loading tool:  1.) Never place a hand or any part of body in fastener discharge area of
tool;  2.) Never point tool at anyone;  3.) Do not pull the trigger or depress the trip as
accidental actuation may occur, possibly causing injury.

OPERATION

Always handle the tool with care:  1.) Never engage in horseplay;  2.) Never pull the trigger
unless nose is directed toward the work;  3.) Keep others a safe distance from the tool while
tool is in operation as accidental actuation may occur, possibly causing injury.

The operator must not hold the trigger pulled on contact arm tools except during fastening
operation as serious injury could result if the trip accidentally contacted someone or
something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool.  A contact arm tool may
bounce from the recoil of driving a fastener and an unwanted second fastener may be
driven possibly causing injury.

Check operation of the contact arm mechanism frequently.  Do not use the tool if the arm
is not working correctly as accidental driving of a fastener may result.  Do not interfere with
the proper operation of the contact arm mechanism.

Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as
this may cause deflection of fasteners which could cause injury. 

Do not drive fasteners close to the edge of the work piece as the wood may split, allowing
the fastener to be deflected possibly causing injury.

MAINTAINING THE TOOL

When working on air tools note the warnings in this manual and use extra care when
evaluating problem tools.

Summary of Contents for N95162

Page 1: ...ENTATIVE OR DISTRIBUTOR ANTES DE OPERAR ESTA HERRAMIENTA TODOS LOS OPERADORES DEBER N ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES MANTENGA...

Page 2: ...eting the specific requirements established for genuine Bostitch nails staples and accessories LIMITED WARRANTY Bostitch Inc warrants to the original retail purchaser that this product is free from de...

Page 3: ...ury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing...

Page 4: ...sm while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneu...

Page 5: ...f wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be k...

Page 6: ...justment feature provides control of the nail drive depth from flush with or just above the work surface to shallow or deep countersink TO ADJUST THE FASTENER DEPTH CONTROL DISCONNECT TOOL FROM AIR SU...

Page 7: ...t trip until the nose touches the work surface and then pull the trigger to drive a fastener Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surfa...

Page 8: ...OOL MUST NOT CYCLE D With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE...

Page 9: ...SEALS When repairing a tool make sure the internal parts are clean and lubricated Use Parker O LUBE or equivalent on all O rings Coat each O ring with O LUBE before assembling Use a small amount of o...

Page 10: ...river to clean Cylinder sleeve not seated correctly on bottom bumper Disassemble to correct Head valve dry Disassemble lubricate Air pressure too low Check air supply equipment Skipping fasteners inte...

Page 11: ...he driving tip to be redressed to compensate for wear Heat and precise measurement are required Contact a qualified service technician for this adjustment The length setting for a new driver is shown...

Page 12: ...ores o accesorios que no cumplen con los requisitos espec ficos establecidos para clavos grapas y accesorios aut nticos de Bostitch GARANTIA LIMITADA Bostitch Inc garantiza al comprador original que e...

Page 13: ...nta est conectada al suministro de aire ya que la herramienta puede ciclarse posiblemente causando lesiones Siempre desconecte el suministro de aire 1 Antes de efectuar ajustes 2 Al hacerle servicio a...

Page 14: ...0 de los 8 9 pies c bicos por minuto cantidad necesaria para operar la herramienta a 100 clavos por minuto OPERACI N BOSTITCH OFRECE DOS TIPOS DE OPERACI N DISPARO POR CONTACTO El procedimiento de ope...

Page 15: ...as Un filtro puede ayudar a obtener el mejor rendimiento y el desgaste m nimo de la herramienta El filtro debe tener una capacidad de flujo adecuada para la instalaci n en particular El filtro debe se...

Page 16: ...lo clavos recomendados por Bostitch para uso en las clavadoras de la serie N95162 de Bostitch o clavos que cumplan con las especificaciones de Bostitch AJUSTE DEL CONTROL DE PROFUNDIDAD DE LOS SUJETAD...

Page 17: ...superficie del objeto a clavar usando fuerza extra En vez de eso permita que la herramienta recule de la superficie del objeto para evitar un segundo sujetador indeseado Quite el dedo del gatillo desp...

Page 18: ...ador de contacto contra la superficie de trabajo LA HERRAMIENTA NO DEBE EFECTUAR SU CICLO D Con el dedo alejado del gatillo presione el disparador de contacto contra la superficie de trabajo Hale el g...

Page 19: ...das Utilice Parker O LUBE o su equivalente en todos los anillos en O Cubra cada anillo en O con O LUBE antes de ensamblar Utilice una cantidad peque a de aceite en todas las superficies y pivotes m vi...

Page 20: ...a manga del cilindro no est asentada Desensamblar para corregir debidamente en el amortiguador de abajo V lvula de cabeza seca Desensamblar lubricar Presi n de aire demasiado baja Verifique el equipo...

Page 21: ...ajustado para permitir que la punta de impulsi n sea rectificada para compensar por el desgaste Se requieren calor y una medici n precisa P ngase en contacto con un t cnico de servicio calificado para...

Page 22: ...atisfont pas aux exigences sp cifiques en vigueur pour les accessoires agrafes et clous garantis d origine BOSTITCH GARANTIE LIMIT E La soci t Bostitch Inc garantit l acheteur original un produit exem...

Page 23: ...sme de contact tant que l outil est connect la source d air car celui ci peut se d clencher et donc provoquer des blessures Toujours d saccoupler l appareil de sa source d nergie 1 avant tout r glage...

Page 24: ...aura besoin de 50 des qui repr sente la quantit d air pour une cadence de 100 clous minute OP RATION BOSTITCH OFFRE DEUX TYPES DE SYST ME DE D CLENCHEMENT LA VOL E Le mode op ratoire ordinaire pour le...

Page 25: ...rendement et une usure minimale du pistolet Le filtre devra avoir une capacit de filtrage ad quate au volume d air consomm par l appareil Le filtre doit tre propre pour alimenter le pistolet en air co...

Page 26: ...e commande permet de contr ler la profondeur d jection du clou depuis le clouage fleur juste au dessus de la surface de travail jusqu au fraisage peu profond ou profond POUR R GLER LA COMMANDE DE PROF...

Page 27: ...l ment d assemblage Ne pas presser trop fort l outil sur la surface Laisser l outil reculer de la surface de travail pour viter l jection d un second l ment ind sir Retirer votre doigt de la d tente...

Page 28: ...t palpeur sur la surface de travail L APPAREIL NE DOIT PAS SE D CLENCHER D D tente libre appuyer l l ment palpeur sur la surface de travail Actionner la d tente L APPAREIL DOIT SE D CLENCHER EN SUPPL...

Page 29: ...s v rifier que les pi ces internes sont propres et bien lubrifi es Appliquer du lubrifiant O LUBE de Parker sur tous les joints toriques avant de proc der l assemblage Appliquer une fine pellicule de...

Page 30: ...du cylindre n est pas positionn e D monter et r installer correctement sur l amortisseur inf rieur Valve de t te s che D monter et lubrifier Pression d air trop faible V rifier le circuit d air l men...

Page 31: ...enfonceur peut tre ajust e pour permettre le redressement de l extr mit de l enfonceur afin de compenser l usure Des mesures pr cises et un chauffage de la pi ce sont n cessaires Veuillez contacter un...

Page 32: ......

Reviews: