background image

TOOL OPERATION

EYE PROTECTION which conforms to ANSI specifications and provides
protection against flying particles both from the FRONT and SIDE should
ALWAYS be worn by the operator and others in the work area when loading,
operating or servicing this tool.  Eye protection is required to guard against
flying fasteners and debris, which could cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn.
Eye protection equipment must conform to the requirements of the
American National Standards Institute, ANSI Z87.1-1989 (R1998) and provide
both frontal and side protection.  NOTE:  Non-side shielded spectacles and
face shields alone do not provide adequate protection.

BEFORE HANDLING OR OPERATING THIS TOOL:

I.  READ AND UNDERSTAND THE WARNINGS CONTAINED IN THIS MANUAL.
II.  REFER TO “TOOL SPECIFICATIONS” IN THIS MANUAL TO IDENTIFY THE 

OPERATING SYSTEM ON YOUR TOOL.

1.  CONTACT TRIP OPERATION:

The CONTACT TRIP MODEL tool contains a contact trip that operates in conjunction with 
the trigger to drive a fastener.  There are two methods of operation to drive fasteners with 
a contact trip tool.

A. SINGLE FASTENER PLACEMENT:  To operate the tool in this manner, first 

position the contact trip on the work surface, WITHOUT PULLING THE TRIGGER.  
Depress the contact trip until the nose touches the work surface and then pull the 
trigger to drive a fastener.  Do not press the tool against the work with extra force.  
Instead, allow the tool to recoil off the work surface to avoid a second unwanted 
fastener.  Remove your finger from the trigger after each operation.

B. RAPID FASTENER OPERATION:  To operate the tool in this manner, hold the 

tool with the contact trip pointing towards but not touching the work surface.  Pull 
the trigger and then tap the contact trip against the work surface using a bouncing 
motion.  Each depression of the contact trip will cause a fastener to be driven.

There are three available systems on BOSTITCH pneumatic tools.  They are:

1. CONTACT TRIP OPERATION   2. SEQUENTIAL TRIP OPERATION   3.TRIGGER OPERATION

The operator must not hold the trigger pulled on contact trip tools except
during fastening operation, as serious injury could result if the trip
accidentally contacted someone or something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool.  A contact
trip tool may bounce from the recoil of driving a fastener and an unwanted
second fastener may be driven, possibly causing injury.

2.  SEQUENTIAL TRIP OPERATION:

The SEQUENTIAL TRIP MODEL contains a contact trip that operates in conjunction with the trigger to
drive a fastener.  To operate a sequential trip tool, first position the contact trip on the work surface
WITHOUT PULLING THE TRIGGER.  Depress the contact trip and then pull the trigger to drive a
fastener.  As long as the contact trip is contacting the work and is held depressed, the tool will drive a
fastener each time the trigger is depressed.  If the contact trip is allowed to leave the work surface, the
sequence described above must be repeated to drive another fastener.

3. TRIGGER OPERATION:

The TRIGGER OPERATED tool requires a single action to drive a fastener. Each time the trigger is 
pulled the tool will drive a fastener. This model does not have a contact trip and is intended for 
use only where a contact trip cannot be used to satisfy the requirements of the application.

10

OPERATION

Summary of Contents for SB-150SLBC

Page 1: ...ARA FUTURA REFERENCIA SI TIENE ALGUNA DUDA COMUN QUESE CON SU REPRESENTANTE DE BOSTITCH O CON SU DISTRIBUIDOR LIRE ATTENTIVEMENT LE PR SENT MANUEL AVANT D UTILISER L APPAREIL PR TER UNE ATTENTION TOUT...

Page 2: ...il purchaser that the product purchased is free from defects in material and workmanship and agrees to repair or replace at Bostitch s option any defective Bostitch branded pneumatic stapler or nailer...

Page 3: ...3 When clearing a jam 4 When tool is not in use 5 When moving to a different work area as accidental actuation may occur possibly causing injury LOADING TOOL When loading tool 1 Never place a hand or...

Page 4: ...under Contact Trip The Sequential Trip Tool has a positive safety advantage because it will not accidentally drive a fastener if the tool is contacted against the work or anything else while the oper...

Page 5: ...wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be ke...

Page 6: ...fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protection is worn Eye protection equipment must conform to the requirements of the Americ...

Page 7: ...Pull up on the pusher for the plastic disks 2 Rotate the pusher out of the magazine 3 Load the plastic disks held together on the plastic pull string 3 4 5 4 Rotate the pusher back into the magazine...

Page 8: ...se 2 Pull pusher back to stop staple feeding 3 Open door in front of nose by releasing latch 4 Remove jammed staple 5 Close door and reconnect latch 6 Bring pusher forward to restart staple feeding 7...

Page 9: ...he air hose Do not alter or modify this tool from the original design or function without approval from BOSTITCH Always be aware that misuse and improper handling of this tool can cause injury to your...

Page 10: ...STENER OPERATION To operate the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip against the wo...

Page 11: ...the trigger and cycle is complete CAUTION THE TOOL WILL CYCLE EACH TIME THE TRIGGER INTERLOCKAND TRIGGER IS PULLED MAINTAINING THE PNEUMATIC TOOL When working on air tools note the warnings in this m...

Page 12: ...eve not seated correctly on bottom bumper Disassemble to correct Head valve dry Disassemble lubricate Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper R...

Page 13: ...13...

Page 14: ...titch L P garantiza al comprador del comerciante original que el producto comprado est exento de defectos en material y fabricaci n y se compromete a reparar o reemplazar a opci n de Bostitch cualquie...

Page 15: ...e efectuar ajustes 2 Al hacerle servicio a la herramienta 3 Al despejar un atascamiento 4 Cuando la herramienta no est en uso 5 Al mudarse de un rea distinta de trabajo ya que se puede activar acciden...

Page 16: ...eguridad porque no aplica accidentalmente un clavo si la herramienta toma contacto con la superficie de trabajo o con otra cosa mientras el operador mantiene el gatillo accionado IDENTIFICACI N DEL MO...

Page 17: ...ltar til un filtro para obtener el mejor rendimiento y minimizar el desgaste de la herramienta El filtro debe tener una capacidad de flujo adecuada para la instalaci n espec fica El filtro debe manten...

Page 18: ...cual puede causar lesiones graves a los ojos El empleador y o el usuario deben asegurar que se protejan debidamente los ojos El equipo de protecci n ocular debe estar en conformidad con los requisito...

Page 19: ...el empujador de los discos de pl stico 2 Gire el empujador para sacarlo del alimentador 3 Cargue los discos de pl stico que est n juntos en la cuerda de pl stico removible 3 4 5 4 Gire el empujador de...

Page 20: ...Jale hacia atr s el empujador para dejar de alimentar grapas 3 Abra la puerta frente a la punta soltando el pestillo 4 Quite la grapa atascada 5 Cierre la puerta y reconecte el pestillo 6 Traiga hacia...

Page 21: ...ltere ni modifique esta herramienta del dise o o funci n original sin la aprobaci n de BOSTITCH Siempre tenga presente que el uso indebido o la manipulaci n incorrecta de esta herramienta puede causar...

Page 22: ...ra usar la herramienta de esta manera sost ngala con el disparo de contacto apuntando hacia la superficie de trabajo pero sin tocarla Accione el gatillo y luego golpee el disparo de contacto contra la...

Page 23: ...car el clavo o grapa Libere el gatillo y se termina el ciclo PRECAUCI N LAHERRAMIENTAHAR UN CICLO CADAVEZ QUE SEACCIONEN EL ENCLAVAMIENTO Y EL GATILLO MANTENIMIENTO DE LA HERRAMIENTA NEUM TICA Al trab...

Page 24: ...ulsor para limpiar El manguito del cilindro no est asentado correctamente en el tope inferior Des rmelo para corregir esto La v lvula cabezal est seca Des rmela y lubr quela La presi n de aire est dem...

Page 25: ...25...

Page 26: ...it est exempt de tout d faut de mat riaux et de fabrication et accepte le cas ch ant de r parer ou de remplacer la discr tion de Bostitch toute agrafeuse ou cloueuse de marque Bostitch d fectueuse pou...

Page 27: ...de sa source d nergie 1 avant tout r glage 2 lors de l entretien 3 lors d un d senrayage 4 la fin de l utilisation 5 lors du d placement vers une nouvelle zone de travail car un d clenchement accident...

Page 28: ...clencheur s quentiel offre un r el avantage de s curit En effet un dispositif ne sera pas accidentellement fix si l outil entre en contact avec l ouvrage ou quoi que ce soit d autre si l op rateur n a...

Page 29: ...e de l usure des outils pneumatiques L utilisation d un filtre permettra d obtenir de meilleures performances ainsi qu une usure minimum de l outil Le filtre doit pouvoir couler l air de fa on ad quat...

Page 30: ...attaches et d bris projet s susceptibles d entra ner des blessures s rieuses L employeur et ou l utilisateur doivent s assurer qu une protection des yeux est port e L quipement de protection doit tre...

Page 31: ...ssoir des disques de plastique 2 Tournez le poussoir pour le sortir du magasin 3 Chargez les disques de plastique tenus ensemble par le fil tirette de plastique 3 4 5 4 Tournez le poussoir pour l enga...

Page 32: ...tractez le pousseur pour arr ter l alimentation en agrafes 3 Ouvrez la porte devant le nez de pose en rel chant le loquet 4 Retirez l agrafe coinc e 5 Refermez la porte et r enclenchez le loquet 6 Ava...

Page 33: ...Ne modifiez pas la conception ou la fonction originale de l outil sans avoir obtenu l accord de BOSTITCH Gardez toujours pr sent l esprit qu une utilisation ou une manipulation incorrecte de cet outil...

Page 34: ...TION RAPIDE D ATTACHES Pour utiliser l outil de cette mani re commencez par tenir la but e de d clenchement au dessus de la surface de travail mais sans tablir le contact Appuyez sur la g chette puis...

Page 35: ...ion Rel chez la g chette le cycle est termin ATTENTION L OUTIL COMMENCE UN CYCLE D S QUE LAS RET EST RETIR E ET QUE LAG CHETTE EST ENCLENCH E MAINTENANCE DE L OUTIL PNEUMATIQUE Lorsque vous travaillez...

Page 36: ...in de corriger le probl me La soupape manque de lubrification D montez lubrifiez La pression d air est trop basse V rifiez l quipement d alimentation d air Saut de dispositifs de fixation alimentation...

Reviews: