3-1
Section 3 • Systems & Components Overview & Operation
255 Conquest
R
Your 255 Conquest is equipped with an (1100 GPH
- 4164 LPH). The pump is activated automatically
by a mercury-free fl oat switch when the water in the
bilge reachs a predetermined level.
By depressing the switch on the control station
labeled BILGE (See fi gure 2.13.1) the operator can
energize the pumps regardless of the position of the
fl oat switches.
The pump discharges water overboard by way of
a thru-hull fi tting on the aft starboard hull (See fi g.
2.5.1).
Maintenance
The pump can be accessed through the aft cockpit
machinery hatch. Frequently inspect the area under
the fl oat switch to ensure it is free from debris and
gummy bilge oil. To clean, soak in heavy duty bilge
cleaner for 10 minutes, agitating several times. Check
for unrestricted operation of the fl oat. Repeat the
cleaning procedure if necessary.
Inspect the bilge pump intake and keep it free
of dirt or material which may impede the fl ow
Bilge Pumps
of water through the pump.
To clean the pump
strainer, depress the lock tabs on both sides of the
pump and lift the pump motor (Figure 3.1.2).
If water does not come out of the discharge hose:
1. Remove the motor module to see if the
impeller rotates with the power on.
2. Remove any debris that may have
accumulated in the impeller section or
strainer base.
3. Check hose and connection on hull side for
debris and proper connections.
B
ILGE
P
UMP
& F
LOAT
S
WITCH
F
IG
. 3.1.2
FLOAT SWITCH
1100 GPH (4164 LPH) PUMP
DISCHARGE
WATER INLET
LOCK TAB
MANUAL TEST KNOB
1
2
3
4
5
6
2
5
6
4
3
Fuel & Oil Spillage
Regulations prohibit discharging fuel or oily waste
in navigable waters. Discharge is defi ned as any
action which causes a fi lm, sheen or discoloration
on the water surface, or causes a sludge or emulsion
beneath the water surface. A common violation is
bilge discharge.
Use rags or sponges to soak up fuel or oily waste,
then dispose of them properly ashore. If there is a
large quantity of fuel or oil in the bilge, contact a
knowledgeable marine service to remove it. Never
pump contaminated bilge discharge overboard.
1
Summary of Contents for 255 Conquest
Page 2: ......
Page 18: ...xviii 255 Conquest R THISPAGE INTENTIONALLY LEFT BLANK ...
Page 90: ...4 6 255 Conquest Section 4 Electrical System R Switch Panel Diagram Fig 4 6 1 ...
Page 91: ...4 7 Section 4 Electrical System 255 Conquest R DC Wiring Diagram Fig 4 7 1 ...
Page 94: ...4 10 255 Conquest Section 4 Electrical System R THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...5 12 Section 5 Care Maintenance R 255 Conquest THIS PAGE LEFT INTENTIONALLY BLANK ...