3-18
370 Outrage
Section 3 • Systems & Components Overview & Operation
R
“Full-Fill” Livewell Operation
• Make sure that the hull seacocks are in the
open position (See fi g. 3.16.1).
• Insert a drain plug (supplied) into the mid
overfl ow drain (See fi g. 3.16.1) and fi ll the
livewell completely. The upper overfl ow
drain will allow the water to rise to just
below the lid before starting to drain.
Maintaining this water level enhances the
stability of the water in the tank.
• Open the livewell fl ow control valves.
The fl ow control valve for the transom
livewell is located behind the access door
on the aft port side of the cockpit
(Figure 3.17.1).
The fl ow control valve for the bait prep station
livewell is located behind the access door on
the front of the leaning post below the
helm seat and behind the drop down standing
platform (Figure 3.17.1).
• Fill the livewellS by pressing the switches
marked “LIVEWELL PUMP” &
“LIVEWELL PUMP AFT” on the bait prep
station switch panel (See page 2-12).
The livewells have three drains to regulate the
amount of water in the unit. The bottom drain is
used to empty the livewell of water completely. By
utilizing the drain plug (supplied) between the two
overfl ow drains in the side of the livewell you can
adjust the level of water in the unit. A drain tube with
strainer connects to the livewell overfl ow drains and
will direct overfl ow/excess water to the thru-hull
drains.
Maintenance
Maintenance of the livewell system requires periodic
inspection of the raw water intake strainer and all
fi ttings and hoses for system integrity to prevent
leaks.
NOTICE
The seacock MUST be in the OPEN position.
Running the pump dry may cause damage to
the unit.
Livewells
Fig. 3.18.1
1
2
3
RAW WATER SWITCH
BAIT PREP STATION LIVEWELL SWITCH
AFT LIVEWELL SWITCH
AFT LIVEWELL ACCESS DOOR
BAIT PREP STATION LIVEWELL
ACCESS DOOR
4
5
PORT FISH
BOX PUMP
STBD FISH
BOX PUMP
FWD FISH
BOX PUMP
RAW WATER
PUMP
LIVEWELL
PUMP
LIVEWELL
LIGHTS
LIVEWELL
PUMP AFT
LIVEWELL
LIGHTS AFT
ACC
1
2
3
4
5
12V
Clean away debris and/or tighten hose connections
as required. The system should be run at least every
other month to keep the pumps impellers in good
condition.
Summary of Contents for 370 Outrage
Page 2: ......
Page 20: ...xx 370 Outrage R THIS PAGE INTENTIONALLY LEFT BLANK...
Page 162: ...4 16 370 Outrage Section 4 Electrical System R Battery Diagram Sheet 1 Fig 4 16 1...
Page 164: ...4 18 370 Outrage Section 4 Electrical System R Helm Breaker Panel Sheet 3 Fig 4 18 1...
Page 168: ...4 22 370 Outrage Section 4 Electrical System R Windlass Schematic Sheet 7 Fig 4 22 1...
Page 170: ...4 24 370 Outrage Section 4 Electrical System R DC Distribution Panel Sheet 9 Fig 4 24 1...
Page 172: ...4 26 370 Outrage Section 4 Electrical System R Hardtop Scematic Sheet 11 Fig 4 26 1...
Page 180: ...4 34 370 Outrage Section 4 Electrical System R Bilge Wiring Schematic Sheet 19 Fig 4 34 1...