R
Livewell
The livewell located in the aft port side of the transom
will keep baitfish alive by circulating fresh seawater
through the tank.
Livewell Operation
• Make sure that the hull seacock is in the open
position (Figure 3.15.1).
• Open the livewell flow control valve
located behind the access door on the
aft port side of the cockpit (See fig. 3.17.1).
The Raw water system includes a pump, seacock
with auxiliary pump, livewell and a raw water hose
connection.
The seacock must be set in the OPEN position for the
raw water system to function. The seacock, livewell
pump and raw water pump can be accessed through
the equipment hatch in the aft cockpit deck.
Make sure that the hull seacock is set in the open
position and turn ON The “WASHDOWN” switch
on the control station switch panel (See page 2.17)
by pushing on the top of the switch. The raw water
pump will be activated and the system will become
functional.
Raw Water System
• Activate the system by depressing the button
on the panel located on the aft port cockpit
(Figure 3.14.1).
Full Cycle (15 minutes)
• Push the start button ONCE. The
system will cycle for 15 minutes per
engine.
• Push the start button TWICE to stop in
the middle of cycle if desired.
Half Cycle (7.5 minutes)
• Push the start button TWICE. The
system will cycle for 7.5 minutes per
engine.
• Push the start button ONCE to stop in
the middle of cycle if desired.
• Fill the livewell by pressing the switch
marked “LIVEWELL” on the console switch
panel (See page 2.17).
The livewell has three drains to regulate the amount
of water in the unit. The bottom drain is used to
empty the livewell of water completely. By utilizing
the drain plug (supplied) between the two overflow
drains in the side of the livewell you can adjust the
level of water in the unit. A drain tube with strainer
connects to the livewell overflow drains and will
direct overflow/excess water to the port thru-hull
drain.
Raw Water Washdown
The raw water washdown hose connection is located
on the port aft wall of the cockpit (fig. 3.17.1). The
fitting allows for connection of a common garden
hose. The raw water washdown is supplied by a
pump activated by the “RAW WATER” switch on
the console switch panel (See page 2.17).
Maintenance
Maintenance of the raw water system requires
periodic inspection of the raw water intake strainer
and all fittings and hoses for system integrity to
prevent leaks.
Clean away debris and/or tighten hose connections
as required. The system should be run at least every
other month to keep the pumps impellers in good
condition.
Raw Water Washdown
Fig. 3.16.1
1
2
3
40 GAL. (151.4 L) LIVEWELL
LIVEWELL FLOW CONTROL ACCESS
RAW WATER WASHDOWN FITTING
1
2
3
Summary of Contents for CONQUEST 345
Page 21: ...xix 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Page 93: ...2 46 Section 2 General Information 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Page 150: ...4 16 345 Conquest Section 4 Electrical System Batteries Joystick Steering Option Fig 4 16 1...
Page 152: ...4 18 345 Conquest Section 4 Electrical System DC MDP Joystick Steering Fig 4 18 1...
Page 154: ...4 20 345 Conquest Section 4 Electrical System AC Power 220V 50Hz Fig 4 20 1...
Page 156: ...4 22 345 Conquest Section 4 Electrical System Cabin O H and Accent Lights Fig 4 22 1...
Page 158: ...4 24 345 Conquest Section 4 Electrical System Wipers and Washers Fig 4 24 1...
Page 160: ...4 26 345 Conquest Section 4 Electrical System Waste System Fig 4 26 1...
Page 161: ...4 27 Section 4 Electrical System 345 Conquest Section 4 Electrical System Windlass Fig 4 27 1...
Page 162: ...4 28 345 Conquest Section 4 Electrical System Trim Tabs Fig 4 28 1...
Page 166: ...4 32 345 Conquest Section 4 Electrical System Pumps Sheet 2 Fig 4 32 1...
Page 168: ...4 34 345 Conquest Section 4 Electrical System V Berth Schematic Fig 4 34 1...
Page 170: ...4 36 345 Conquest Section 4 Electrical System Shore Power 230V 50HZ Fig 4 36 1...
Page 172: ...4 38 345 Conquest Section 4 Electrical System Stereo Premium Option Fig 4 38 1...
Page 174: ...4 40 345 Conquest Section 4 Electrical System Heater CO Monitor Fig 4 40 1...
Page 176: ...4 42 345 Conquest Section 4 Electrical System Generator 230V 50Hz Fig 4 42 1...
Page 178: ...4 44 345 Conquest Section 4 Electrical System STBD AC Harness Fig 4 42 1...
Page 180: ...4 46 345 Conquest Section 4 Electrical System STBD DC Harness Fig 4 44 1...
Page 182: ...4 48 345 Conquest Section 4 Electrical System Windlass Harness Fig 4 46 1...
Page 206: ...5 22 Section 5 Care Maintenance 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...