1-7
345 Conquest
345 Conquest
Section 1• Safety
Your CO detector is equipped with an End Of Life
(EOL) signal indicating the sensor used in the unit
has reached the end of it’s service life and must be
replaced. The signal is activated from a timer that
will run for 7 years from the date of manufacture.
Depending on your monitor, the EOL signal indica-
tor varies, so check the unit’s operation manual for
further information and instructions.
The EOL signal can be reset for a period of 72 hours
(3 days) for a total of up to 30 days. After this time,
the unit will continuously signal EOL and will no
longer detect CO and MUST BE REPLACED! DO
NOT DISCONNECT THE ALARM UNTIL YOU
HAVE A REPLACEMENT ALARM AVAILABLE
TO INSTALL! REMOVING THE LITHIUM BAT-
TERY WILL CAUSE THE UNIT TO SIGNAL
EOL PERMANENTLY.
End Of Life signal
In the event an alarm activates:
• Evacuate enclosed areas immediately.
• Shut OFF any fuel burning equipment or
appliances.
• Open hatches, doors, portlights, etc. to
improve ventilation.
• If making way, head boat into the wind.
XINTEX
MARINE
CARBON MONOXIDE ALARM
TEST/
MUTE
ON
MOVE TO
FRESH AIR
Carbon Monoxide Detector
Fig. 1.7.1
POWER INDICATOR
DANGER INDICATOR
TEST/SILENCE BUTTON
HORN
1
2
4
3
1
2
4
3
The alarm will simulate 2 alarm cycles (2 sets of 4
beeps, 5 sec. silence between). The Red LED will
flash once every 5 seconds.
Maintenance:
Avoid spraying liquids directly on alarm.
!
DANGER
Even in rainy cold weather, ventilation must be
maintained to avoid Carbon Monoxide poisoning.
You will get wet and/or cold.
• Be sure to have sufficient ventilation when
using canvas enclosure.
• Open all forward hatches and leave cabin door
open.
• Operate all fuel burning appliances, such as
charcoal, propane, LPG, CNG or alcohol
cooking devices in areas where fresh air can
circulate.
• Do not idle the engine(s) without moving the
boat for more than 15 minutes at a time.
• Inspect the bilge blower, located aft of the
generator in the equipment compartment and the
head exhaust blower located behind the Vacu-
Flush
®
unit regularly.
Carbon Monoxide Detectors
There are two (2) Carbon Monoxide Detectors on
your boat. One is located on the port side of the
forward cabin and the second is located on the
starboard side of the mid cabin. The detectors are
very sensitive and will notify you before dangerous
amounts of Carbon Monoxide can accumulate which
will allow you to take measures to dissipate the gas
from the affected areas.
Read and understand the warnings and
recommendations presented in this section to help
keep yourself and your passengers safe from CO.
Testing:
At least once a week
depress the “Test/
Mute” button until the green LED turns on and
release to determine if the detector is working
properly.
This detector will only indicate the presence of carbon monoxide
gas at the sensor. Carbon monoxide may be present in other
areas.
!
CAUTION
Summary of Contents for CONQUEST 345
Page 21: ...xix 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Page 93: ...2 46 Section 2 General Information 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Page 150: ...4 16 345 Conquest Section 4 Electrical System Batteries Joystick Steering Option Fig 4 16 1...
Page 152: ...4 18 345 Conquest Section 4 Electrical System DC MDP Joystick Steering Fig 4 18 1...
Page 154: ...4 20 345 Conquest Section 4 Electrical System AC Power 220V 50Hz Fig 4 20 1...
Page 156: ...4 22 345 Conquest Section 4 Electrical System Cabin O H and Accent Lights Fig 4 22 1...
Page 158: ...4 24 345 Conquest Section 4 Electrical System Wipers and Washers Fig 4 24 1...
Page 160: ...4 26 345 Conquest Section 4 Electrical System Waste System Fig 4 26 1...
Page 161: ...4 27 Section 4 Electrical System 345 Conquest Section 4 Electrical System Windlass Fig 4 27 1...
Page 162: ...4 28 345 Conquest Section 4 Electrical System Trim Tabs Fig 4 28 1...
Page 166: ...4 32 345 Conquest Section 4 Electrical System Pumps Sheet 2 Fig 4 32 1...
Page 168: ...4 34 345 Conquest Section 4 Electrical System V Berth Schematic Fig 4 34 1...
Page 170: ...4 36 345 Conquest Section 4 Electrical System Shore Power 230V 50HZ Fig 4 36 1...
Page 172: ...4 38 345 Conquest Section 4 Electrical System Stereo Premium Option Fig 4 38 1...
Page 174: ...4 40 345 Conquest Section 4 Electrical System Heater CO Monitor Fig 4 40 1...
Page 176: ...4 42 345 Conquest Section 4 Electrical System Generator 230V 50Hz Fig 4 42 1...
Page 178: ...4 44 345 Conquest Section 4 Electrical System STBD AC Harness Fig 4 42 1...
Page 180: ...4 46 345 Conquest Section 4 Electrical System STBD DC Harness Fig 4 44 1...
Page 182: ...4 48 345 Conquest Section 4 Electrical System Windlass Harness Fig 4 46 1...
Page 206: ...5 22 Section 5 Care Maintenance 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...