Tips: If you cannot solve the corresponding fault according to our guidelines or
the fault does not appear in the error code list, please feel free to let us know
via email or phone.
Error Code & Troubleshooting
The output will be cut off
when the battery
temperature is over 63
℃
/145°F
Press the AC button 2s to eliminate
it. Let the G1000 stand for a period of
time until the temperature drops, it
can output normally
07: Battery
high
temperature
protection
(Output)
The input will be cut off
when the battery
temperature is over 47
℃
/117°F
Automatically restart charging when
the temperature is below 47
℃
/117°F
10: Battery
high
temperature
protection
(Input)
The input will be cut off
when the battery
temperature is below -3
℃
/27°F
Automatically restart charging when
the temperature is over -3
℃
/27°F
11: Battery low
temperature
protection
(Input)
Automatically cut off the
input when DC & PV input
voltage over 30V
We recommended that you use the
original AC adapter to charge; when
PV charging, we recommended you
use ≤ 200W solar panels
12: Input
ove-rvoltage
protection
The voltage will drop
when the battery capacity
is low, and the output will
be cut off when the
voltage is below 18V
It is recommended to charge the
battery in time when the battery
capacity is less than 10%; When the
battery capacity is low, we recom-
mended you not to use low-power
DC appliances to carry for a long
time
13: Battery
low-voltage
protection
The output will be cut off
when the battery
temperature is over -10
℃
/14°F
08: Battery
low tempera-
ture protec-
tion (Output)
Press the AC button 2s to eliminate
it. Put the G1000 in an environment
above 0
℃
/32°F, it can output
normally
Error Code
Explanation
Troubleshooting