Phenomenon

No cool enough

Check whether it is set to the cooling mode and 
whether the temperature setting is too high.
The temperature range of the air conditioner is 16-30 
degrees. When the ambient temperature reaches the 
setting, the compressor and fan will stop running.
When the ambient environment is lower than 16 
degrees, the air conditioner does not turn on, which 
is normal.

Cooling slow

Space is too large, please make sure the space within 
3 square meters.

Outlet air is hot

E1

E6

Under-Voltage 
Protection

Sensor Error
(short circuit, open circuit)

Check whether the adapter is 
faulty or whether the 24V DC 
power‘s voltage is lower than 
21.5V, and the error is removed 
when the voltage rises to 23V.

Check if the temperature 
sensor is disconnected

If the air outlet is not cold, you can check whether the 
compressor is turned on. When the ambient 
temperature is too high, try to run the air conditioner 
with a moderate fan speed to reduce the load of the 
compressor.

Measure

Error Code Explanation

Troubleshooting

Summary of Contents for E0501-07002

Page 1: ...E0501 07002 Portable Air Conditioners User Manual...

Page 2: ......

Page 3: ...haser Please provide the screenshot of the order from Amazon or the website in order to affirm the warranty start date Tips If there is any problem with the product you can provide us with pictures an...

Page 4: ...by the consumer not following the recommendations Damage caused by disassembling the machine without authorization or maintained by a non designated mainte nance site Products purchased neither on Bou...

Page 5: ...ble of Contents Product Introduction Package List Product Safety Guidelines Preparation Before Use Operating Instructions Error Code Troubleshooting Cleaning Tips Specifications FAQs 1 2 3 4 6 7 9 9 1...

Page 6: ...Exhaust Air Outlet Exhaust Air Inlet Pipe Drain Power Input Control Panel Cooling Air Outlet Cooling Air Inlet Exhaust Air Cycling Cooling Air Cycling Product Introduction 1...

Page 7: ...f any of these is missing please feel free to contact us via service bougerv com E0501 07002 1 360W AC Adapter 1 24V DC Power Cord 1 User Manual 1 Venting Hose Head 3 Venting Hose Tail 3 Venting Hose...

Page 8: ...clean directly with water 5 Do not use this air conditioner near flammable materials or in a sealed space Keep the air clean and flowing 6 This product contains compressors and refrigerants non pro f...

Page 9: ...emselves Preparation Before Use 1 Plug The Power Plug 110V 220V power with 24V AC adapter Plug directly to a 24V DC power with the included DC power cord 12V 24V inverter Connect to the 24V port with...

Page 10: ...in outlet to the outside of the tent 2 The water outlet of the drain pipe must be lower than the bottom of the air conditioner it will cause poor drainage 3 If you want to move the air conditioner aft...

Page 11: ...Switch between fan mode compressor does not turn on and cooling mode Adjust the fan speed in three gears Increase or decrease the temperature 1 Fan Mode 2 Button 3 Button 4 Power Button 5 Cooling Ico...

Page 12: ...ient temperature drops to the set temperature the system will reduce power consumption and cooling capacity and the compressor and fan will stop When the ambient tem perature is higher than the set te...

Page 13: ...large please make sure the space within 3 square meters Outlet air is hot E1 E6 Under Voltage Protection Sensor Error short circuit open circuit Check whether the adapter is faulty or whether the 24V...

Page 14: ...ong time the power should be unplugged and the water should be drained 3 Keep away from fire Model Cooling capacity Rated Voltage Rated Current Refrigerant Sound Level Moisture Protection Product Dime...

Page 15: ...r conditioner does not support photovoltaic input you can only use AC 110 220V or DC 24V power supply Q3 In addition to tent cooling can I use the air condi tioner for indoor or more scenes A Differen...

Page 16: ......

Reviews: