18
TROUBLESHOOTING GUIDE
SYMPTOM
CAUSE
SOLUTION
Detector chatters,
• Using detector
• Use detector
beeps erratically
indoors
outdoors only
or has low
• Using detector near • Move away
sensitivity
power lines
from power lines
• Using 2 detectors in • Keep 2 detectors
close proximity
at least 6 meters
(20’) apart
• Environmental
• Reduce sensitivity
electromagnetic
until erratic
interference
signals cease
Low speaker
• Discharged battery
• Replace battery
volume
• Wrong type of
• Use
alkaline
battery
batteries
Display does not lock • Multiple targets
• Sweep coil at
on to one Target-ID
present
different angles
or detector emits
• Highly mineralized
• Move to a
multiple tones
soil
different area
• Sensitivity set
too high
• Reduce sensitivity
No power, no sounds • Dead battery
• Replace batteries
• Cable not connected • Check connections
securely
Do not mix old and new batteries.
Use alkaline batteries.
Do not mix alkaline, standard (zinc-carbon), or
rechargeable (NiCad, NiMH, etc.) batteries.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Consult the dealer or an experienced radio/TV technician for help.
CE
The manufacturer declares that the minimum ESD performance criteria is 1) the unit shall not
be permanently damaged and 2) operator intervention is allowed.
This product is RoHS compliant.
This product meets the requirements of Industry Canada: CAN ICES-3 B/NMB-3 B.