background image

 04

 

 

 

 

 

 

 

 

Servicing and maintenance

 

Lubrication

 

The following moving parts of the Supermatch 6&8 need top be lubricated once a month, particularly if the trap is left 
outside in all weather conditions. We use a chain oil lubricant CD90 for lubricating moving parts. GT85 is used as a 
water displacement spray to protect motors, wires and the main spring from damp conditions and for cleaning out 
clay dust from moving parts. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure that the joint remains          
lubricated and free moving so the push 
bar can index the carousel.

 

 

Ensure moving joints powered by the 
motor are well lubricated 

 

 

Lubricate these areas. Avoid putting any grease 
onto the plate of the throwing arm. 

 

Electric Box

 

The motor is protected by either a fuse or circuit breaker housed in the control box. If the fuse is activated it can 
easily be replaced. Two spare fuses are supplied in the control box. If the circuit breaker is activated the Thermal 
Overload reset button will pop up to cut the power. 

Before replacing the fuse or pressing the Thermal Over-

load reset button to re

-

activate the trap you must turn the 3 position switch to off and disconnect the 

battery to investigate the reason for the malfunction

.

 Most commonly this is because of a flat battery or the 

throwing arm is jammed. 

Please be aware the throwing arm may be parked in a dangerous position so be 

careful not to place yourself in harms way while you investigate or when you re

-

activate the trap.   

 

Summary of Contents for COMPACT 150

Page 1: ... position or the bowman mini barrow If you have purchased a Bowman mini barrow position the trap onto the barrow and line up the 4 bolt holes Use the 10mm bolts provided to secure your trap to the mini barrow A washer should be placed on either side a spring washer goes on before the nut to secure Key Points Check your contents Read thoroughly before attempting to assemble or operate Do not attemp...

Page 2: ...pring detached Remove the cable ties carefully to access the parts Place the washers and spacers carefully to the side in the order they were attached to the tension bar To re attach the main spring rotate the throwing arm until it points straight ahead In this position there is no tension on the main spring allowing you to fit the M12 studding through the spring tension bar at the rear Once throu...

Page 3: ... terminals ensuring the program switch is set to off and then switch the program to on run in preparation to fire clays Adjusting advance and retard limit switch The Limit Switch is set to stop the throwing arm just before it goes over centre and fires We set this at the facto ry however if the arm stops too far from the clay or too close to the centre causing auto firing please follow these instr...

Page 4: ... any grease onto the plate of the throwing arm Electric Box The motor is protected by either a fuse or circuit breaker housed in the control box If the fuse is activated it can easily be replaced Two spare fuses are supplied in the control box If the circuit breaker is activated the Thermal Overload reset button will pop up to cut the power Before replacing the fuse or pressing the Thermal Over lo...

Reviews: