Service Manual 04/2010 Rev.B
68
FAIULURE #1 ALSO MAY BE CAUSED BE A
MECHANICAL MALFUNCTION OF THE SHUT
OFF SWITCH PROTECTION.
BEFORE STARTING WITH ANY ELECTRICAL
CONTROL VERIFY IF THE PROTECTION IS
WELL REGULATED AND IF IT MOVES UP AND
DOWN FREELY.
TO CONTROL THE CABLE:
Disconnect the machine from power supply.
Open the electric box (
5.0).
Disconnect the wires 10 and 11 from terminal
block into electric box (Fig.104).
Fig.104
Open the shut off switch S4 cover and
disconnect both wires (Fig.105).
Take a multimeter and select it in Ohm.
Position the multimeter probes on the ends of
same wire and verify if there is continuity (
Ω
=
0 ~ 0,3).
If there is not continuity the wire must be
replaced.
Fig.105
TO REPLACE THE CABLE:
Disconnect the machine from power supply.
Open the electric box (
5.0).
Disconnect the wires 10 and 11 from terminal
block.
Open the shut off switch S4 cover and
disconnect both wires (Fig.105).
Release the strains cable relief on electric
box.
Take the defective cable away.
Insert the new cable.
Tighten the wires on the switch S4 and on the
terminals block
FIRMLY
.
Lock the switch S4 cover and tighten the
screws
FIRMLY
.
IMPORTANT: WHEN CLOSING THE
SWITCH DOOR BE CAREFUL NOT TO
CRUSH WIRES.
Tighten the strain cable relief leaving some
cable free (Fig.105).
5.19 SHUT OFF SWITCH S4: CHECK
AND REPLACEMENT
:
1h
:
Small standard screwdriver, multimeter ,
pliers, end wrench 13mm, Allen wrench 4mm,
loctite.
L
:
Defective shut off switch may cause the
following malfunction:
3. The chuck arm does not come down.
5.0 Fuse F7 blows up.
IMPORTANT!
FAIULURE #1 ALSO MAY BE CAUSED BY A
MECHANICAL MALFUNCTION OF THE SHUT
OFF SWITCH SAFETY LEVER.
BEFORE STARTING WITH ANY ELECTRICAL
CONTROL VERIFY IF THE PROTECTION IS
WELL REGULATED AND IF IT MOVES UP AND
DOWN FREELY.
TO CONTROL THE SWITCH:
Disconnect the machine from power supply.
Open the electric box (
5.1).
Disconnect the wires 10 and 11 from terminal
block.
Open the shut off switch S4 door and
disconnect both wires (Fig.105).
Take a multimeter and select it in Ohm.
Position the multimeter probes on the switch
terminals and verify if there is continuity (
Ω
=
0 ~ 0,3).
If there is not continuity the switch must be
replaced.
TO REPLACE THE SWITCH:
Release the strain cable relief on chuck arm.
Remove the defective switch.
Install the new switch.
Summary of Contents for KING 5600
Page 9: ...Service Manual 04 2010 Rev B 9 3 1 ELECTRIC DIAGRAM FOR CE PROVED KING 5600 Fig 16...
Page 10: ...Service Manual 04 2010 Rev B 10 Fig 17...
Page 11: ...Service Manual 04 2010 Rev B 11 Fig 18...
Page 12: ...Service Manual 04 2010 Rev B 12 Fig 19...
Page 13: ...Service Manual 04 2010 Rev B 13 Fig 20...
Page 14: ...Service Manual 04 2010 Rev B 14 Fig 21...
Page 15: ...Service Manual 04 2010 Rev B 15 Fig 22...
Page 16: ...Service Manual 04 2010 Rev B 16 Fig 23...
Page 17: ...Service Manual 04 2010 Rev B 17 3 2 ELECTRIC DIAGRAM FOR KING SUPPLIED AT 200V 3PH 60Hz Fig 24...
Page 18: ...Service Manual 04 2010 Rev B 18 Fig 25...
Page 19: ...Service Manual 04 2010 Rev B 19 Fig 26...
Page 20: ...Service Manual 04 2010 Rev B 20 Fig 27...
Page 21: ...Service Manual 04 2010 Rev B 21 Fig 28...
Page 22: ...Service Manual 04 2010 Rev B 22 Fig 29...
Page 23: ...Service Manual 04 2010 Rev B 23 Fig 30...
Page 24: ...Service Manual 04 2010 Rev B 24 Fig 31...
Page 25: ...Service Manual 04 2010 Rev B 25 3 3 ELECTRIC DIAGRAM FOR CE APPROVED KING 5600R Fig 32...
Page 26: ...Service Manual 04 2010 Rev B 26 Fig 33...
Page 27: ...Service Manual 04 2010 Rev B 27 Fig 34...
Page 28: ...Service Manual 04 2010 Rev B 28 Fig 35...
Page 29: ...Service Manual 04 2010 Rev B 29 Fig 36...
Page 30: ...Service Manual 04 2010 Rev B 30 Fig 37...
Page 31: ...Service Manual 04 2010 Rev B 31 Fig 38...
Page 32: ...Service Manual 04 2010 Rev B 32 Fig 39...
Page 34: ...Service Manual 04 2010 Rev B 34 Fig 41...
Page 35: ...Service Manual 04 2010 Rev B 35 Fig 42...
Page 36: ...Service Manual 04 2010 Rev B 36 Fig 43...
Page 37: ...Service Manual 04 2010 Rev B 37 Fig 44...
Page 38: ...Service Manual 04 2010 Rev B 38 Fig 45...
Page 39: ...Service Manual 04 2010 Rev B 39 Fig 46...
Page 40: ...Service Manual 04 2010 Rev B 40 Fig 47...
Page 41: ...Service Manual 04 2010 Rev B 41 3 5 HYDRAULIC DIAGRAM FOR CE APPROVED KING 5600 Fig 48...
Page 42: ...Service Manual 04 2010 Rev B 42 Fig 49...
Page 43: ...Service Manual 04 2010 Rev B 43 3 6HYDRAULIC DIAGRAM FOR KING 5600 Fig 50...
Page 44: ...Service Manual 04 2010 Rev B 44 Fig 51...
Page 45: ...Service Manual 04 2010 Rev B 45 3 7 HYDRAULIC DIAGRAM FOR CE APPROVED KING 5600R Fig 52...
Page 46: ...Service Manual 04 2010 Rev B 46 Fig 53...
Page 47: ...Service Manual 04 2010 Rev B 47 3 8 HYDRAULIC DIAGRAM FOR MACHINE NON CE KING 5600R Fig 54...
Page 48: ...Service Manual 04 2010 Rev B 48 Fig 55...
Page 138: ...Service Manual 04 2010 Rev B 138 BLANK PAGE...