Putting into operation
Sprühboy 04s - Airless Edition 10.12
4.3
Fill the Sprühboy 04s with the
required agent pressure
It is imperative that you comply with the
chapter "General requirements on the
compressed air source", page 12.
The external compressed air source
must supply a minimum pressure of 5
bar.
The desired spray pattern determines
the required agent pressure.
The agent pressure must be at least
5 bar to result in a reasonable spray
pattern.
The bleed valve (1) opens if the
maximum
permissible
implement
pressure of 6 bar is exceeded.
- Connect the compressed air connection (2) from
the Sprühboy 04s via the spiral hose (3) to an
external compressed air source, here to the
compressed
air
connection
(4)
from
the
compressor
Airboy 04.
The external compressed air source fills
the Sprühboy 04s with compressed air.
- Switch on the compressor Airboy 04. The
compressor starts and fills the Sprühboy 04s with
compressed air. If the permissible operating
pressure (6 bar) has been reached, the
compressor switches off automatically.
- Pull the spiral hose off the compressed air
connection (2) on the Sprühboy 04s.
- The Sprühboy 04s is now ready for operation.