Cleaning, maintenance and repair
19
Sprühboy 04s - Airless Edition 10.12
5.2.1
Spray gun and agent-hose
If you do not wish to clean the entire system, the
cleaning adapter WRA (1) facilitates rapid cleaning of
spray gun and agent-hose at the end of a production
run.
However, for hygienic reasons, rapid
cleaning of spray gun and agent-hose
cannot replace complete cleaning, as
described in chapter "Complete device",
page 20.
- Pull the rapid coupling (1) from the agent vessel
connection piece (2).
- Connect the cleaning adapter WAR (1) to a water
pipe carrying hot water.
- Connect rapid coupling (2) and cleaning adapter
WAR (1).
- Turn on the water supply and spray until a clean,
clear jet of water issues from the spray gun. If
clear water issues from the spray gun, the agent
channel has been cleaned.